Chapter 11. Dial Plan61200305L1-1 ATLAS 550 User Manual 11-9G LOBAL P ARAM Sets ATLAS 550 options which apply to all switched operations, both incom-ing and outgoing calls.E ND OF NUMBERTIMEOUTWrite security: 3; Read security: 5Sets the length of time ATLAS 550 waits before assuming the outgoingdialed number is complete. The default value is six seconds. This timeoutwill only be invoked if the dialed number does not match one of the pat-terns set in the Number Complete Template menu (see the section, NbrComplete Templates on page 11-9).AREA CODE Write security: 3; Read security: 5The local area code. Use for sending caller ID to the Network.NBR COMPLETETEMPLATESWrite security: 2; Read security: 5Sets completed number patterns for outgoing calls so that ATLAS 550recognizes when the phone number is complete. Fields include the indexnumber (#) and PATTERN. For example, a local number will be 7 digits longwhile a long distance (1+ area code + number) will be 11 digits long. TheATLAS 550 defaults cover almost any installation, and these templatesshould not require any additional user input—except for unusualcircumstances. The template allows the use of the following wild cardinputs to define numbers:NUMBER T YPETEMPLATESWrite security: 2; Read security: 5Sets call type patterns. ISDN interfaces require that a number type be sentover the D channel when a call is sent or received. A normal RBS trunk doesnot send a type designator, but uses prefixes instead. For example, “1 +”prefix is a national long distance call type while a “011 +” prefix is an inter-national long distance call type. These templates form a table to permitATLAS 550 to translate the RBS prefix into a call type for ISDN and vice-versa.# Denotes an entry number. The maximum number of entries is 50. Press I toinsert a new entry and D to delete any entry.P REFIX Sets the prefix for the number type. Only digits 0 and 1 are allowed (MAX 6).X = Any single digitN = Any single digit 2 through 9911 = This specific number[1, 2, 3...] = A single digit in this groupThe ATLAS 550 default templates should cover all applications andshould not need to be added to by the user except for very rarecircumstances.