MX2820 System Manual5-18 61186003L1-1DSHELF ALARMSView the status of shelf alarms by selecting the following options:• Select S YSTEM A LARMS, from the MX2820 Main Menu, and press E NTER.• Select S HELF ALARM STATUS, from the System Alarms menu, and press E NTER.• Return to the MX2820 Main Menu by pressing E SC until the menu appears.Figure 5-6 shows an example of the Shelf Alarm screen for a 19-inch shelf.Menu selections are as follows:• M displays the Master alarm log.• S displays the SCU alarm log.• A number from 1 to 7 (19-inch shelf) or from 1 to 9 (23-inch shelf) displays the alarm logfor the M13 or STS-1 MUX module that occupies the slot location.• C displays the Clock Module log.Figure 5-6. Shelf Alarms Status Screen (19-inch shelf)Shelf: 1 ADTRAN MX2820 System 04/21/04 23:05Unacknowledged Alarms: None TID: HTVLALEXD16Shelf Alarm StatusM Master LogS SCU......... [Major]C A - MX2820 SMC.. [None] B - ............ [None]1 A - MX2820 M13.. [Critical] B - MX2820 M13.. [None]2 A - ............ [None] B - ............ [None]3 A - ............ [None] B - ............ [None]4 A - MX2820 STS1. [None] B - ............ [None]5 A - ............ [None] B - ............ [None]6 A - ............ [None] B - ............ [None]7 A - ............ [None] B - ............ [None]Select Log (M-Master, S-SCU, C-CLK, 1..7):