MX2820 System Manual7-86 61186003L1-1DMATERIALS REQUIRED• Data cable to connect to the VT100 terminal or PC configured as a VT100 terminal• VT100 terminal or PC configured as a VT100 terminalWARNINGTo prevent electrical shock, do not install equipment in a wet loca-tion or during a lightning storm.CAUTIONElectronic modules can be damaged by static electrical discharge.Before handling modules, wear an antistatic discharge wrist strapto prevent damage to electronic components. Place modules inantistatic packing material when transporting or storing. Whenworking on modules, always place them on an approved antistaticmat that is electrically grounded.PROCEDURE1. Connect the VT100 terminal or PC to the craft port on the front panel of the SCU. Fordetails, refer to DLP-715.2. Logon to the system. For details, refer to DLP-716.3. From the MX2820 Main Menu, select S YSTEM C ONTROLLER and press E NTER.4. From the System Controller menu, select P ROVISIONING and press E NTER.5. From the Provisioning menu, select TL1 and press E NTER.6. From the TL1 menu, select S YSTEM N AME and press E NTER.7. Input the TIRKS ID (TID), following the rules listed below, and press E NTER.The rules for TID usage are as follows:• TID characters must be upper case only• The first entry must be a letter• The final entry must be a letter or number (no symbols)• The only symbol allowed in the TID is the dash (–)• The TID length is limited to 20 charactersExample: The TID that the TIRKS group issues consists of an 11 digit code similar to theformat HTALEXD16.This TID is decoded as follows:• HTVL designates the city• AL designates the state