Section 5, User Interface Guide - UIG-525, STS-1 MUX PM Statistics61186003L1-1D 5-73STS-1 Far-End Daily Thresholds and AlarmsSelect F AR E ND DAILY T HRESHOLDS from the STS-1 Statistics menu screen.Figure 5-40 shows an example of the Far-End Daily Thresholds menu screen.Figure 5-40. STS-1 Far-End Daily ThresholdsInput the number of the desired PM parameter, and press E NTER.The menu screen for the selected PM parameter appears. The user is then able to set thethreshold to the desired level and enable/disable an alarm to be issued once that threshold isexceeded.NOTEOptions at the bottom of the menu are used to restore all STS-1and VT/Port threshold defaults.Shelf: 1 Slot: 4A ADTRAN MX2820 System 04/16/04 09:10Unacknowledged Alarms: None TID: HTVLALEXD16STS-1 Statistics - Far End Daily ThresholdsThreshold Alarm1 - CV-L : 382 Disabled2 - ES-L : 25 Disabled3 - SES-L : 4 Disabled4 - UAS-L : 10 Disabled5 - CV-P : 382 Disabled6 - ES-P : 25 Disabled7 - SES-P : 4 Disabled8 - UAS-P : 10 Disabled9 - Restore ALL STS-1, VT, and DS1 Threshold Defaults10 - Enable ALL STS-1, VT, and DS1 Threshold Alarms11 - Disable ALL STS-1, VT, and DS1 Threshold AlarmsSelection: '?' - System Help Screen