Section 5, User Interface Guide - UIG-520, M13 MUX PM Statistics61186003L1-1D 5-53T1/E1 Near-End Quarter Hourly StatisticsNOTET1/E1 near-end quarter-hourly statistics are maintained for thecurrent15-minute interval and the completed 96 previous 15-minute inter-vals (providing a 24-hour history). A total is also provided that rep-resents the sum of the previous 96 15-minute intervals.Select N EAR E ND Q UARTER H OURLY from the T1/E1 Statistics screen, and select a desired T1/E1circuit.Figure 5-26 (see Figure 5-27 for P/N 1186002L3) shows an example of the near-end quarter-hourly statistics for the T1 #1 circuit.Figure 5-26. T1 #1 Near-End Quarter Hourly Statistics (Example)Shelf: 1 Slot: 4A ADTRAN MX2820 System 04/15/04 02:44Unacknowledged Alarms: None TID: HTVLALEXD16T1/E1 Statistics - Near End Quarter HourlyT1 #1Current Total 19:45 19:30 19:15 19:00 18:45 18:30CV-L 0 0 0 0 0 0 0 0ES-L 0 0 0 0 0 0 0 0SES-L 0 0 0 0 0 0 0 0LOSS-L 0 0 0 0 0 0 0 0AISS-P 0 0 0 0 0 0 0 0Select Interval: (B) to go Back. '?' - System Help Screen