2-6Ultra160 Family Manager Set User’s Guiden Maximum SGList — Specifies the maximum number ofScatter/Gather elements. Valid values are 17-255. The datatype for this value is REG_DWORD.To enter Windows NT parameters, follow these steps:1 Select Run from the Start button.2 Type regedt32 and press Enter.3 Open the registry list to the following location:\HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\adpu160m\Parameters\DeviceIf the Parameters Device keys already exist, skip to Step 8below to begin entering values. If the keys do not yet exist, youwill need to create them by continuing with Step 4.4 Click on the adpu160m key.5 Select Add Key from the Edit menu; Type Parameters in theKey Name edit box. Leave the Class edit box blank.6 Click on the Parameters key.7 Select Add Key from the Edit menu; Type Device in the KeyName edit box. Leave the Class edit box blank.To specify a certain host adapter, append Device with thenumber of the host adapter. For example, type Device0 for thefirst host adapter, Device1 for the second, etc. If you omit thehost adapter number, the configuration information applies toall Ultra160 Family host adapters.8 Click on the Device key.9 Select Add Value from the Edit menu. In the Value Name editbox, enter one of the valid parameter values. Make sure toenter the appropriate data type for the value. To enteradditional values, repeat Steps 8 and 9.Note: Changes made with the Registry Editor do not takeeffect until you shut down and then restart your system.