Maximum Edge StrengthThe greatest rate of change value observed by the tool.Available when the Threshold Type is set to Edge Strength.Execution TimeThe execution time, in milliseconds, for the currently selected tool in the current inspection.Expand Execution Time to see the historical minimum and maximum execution times up to this point for the selected tool.Use the reset button in the Inspection Summary to reset these historical values.StatusStatus and error messages display as appropriate.8.10.4 Using the Object ToolFollow these steps for an example Object inspection.This example verifies the number and position of pins on a connector by analyzing the size of the two gaps between the pins.Note: This procedure is an example only.1. Add an Object tool to the inspection.2. Adjust the position, length, and width of the ROI.a) Move the ROI so that it crosses all of the pins.b) Leave the default ROI width (13 px).Figure 248. Object Tool3. Set the threshold.a) Expand the Threshold parameters.b) Leave the Threshold Type as the default (Relative).c) Leave the Percent as the default (50).d) Select Dark from the Object Type list.4. Set the Test parameters to set the pass/fail criteria.a) Expand Individual Objects.b) Select the All Dark Width Range checkbox to enable the parameter.c) Move the sliders or enter the minimum as 141.48 and the maximum as 252.96.5. Test a complete range of good and bad samples to make sure that the sensor accepts good parts and rejects bad parts.Figure 249. Good Part Figure 250. Bad Part—Bent PinVE Series Smart Camerawww.bannerengineering.com - Tel: 763.544.3164 125