12. Click Assign name to start the process.The name is assigned.Figure 366. Assign Name13.7 Troubleshooting13.7.1 Industrial Ethernet Error CodesThe VE Series camera provides error codes when coil bit commands fail to execute successfully.If such an error occurs, the Execution Error flag is set in the Output Bits/Status Register. When this bit is set, read the Error Code registerto know the reason for the failure.Error Code Description Recommended Solution520 The coil action resulted in a failure. Clear all coil bits. Verify that the corresponding acknowledgement bits arereset to zero. The error code will clear when the next valid command isissued.524 Multiple coils were assertedsimultaneously. Clear all coil bits. Verify that the corresponding acknowledgement bits arereset to zero. The error code will clear when the next valid command isissued.80400 The sensor must be in the Ready stateto perform a product change. Clear the Product Change bit. Verify that the Product Changeacknowledgement bit has been reset to zero. Wait until the sensor is Ready.Re-assert the Product Change bit.80401 Attempt to product change to aunknown or invalid inspection. Clear the Product Change bit. Verify that the Product Changeacknowledgement bit has been reset to zero. Set the inspection slot to avalid value. Re-assert the Product Change bit.13.7.2 PROFINETDiscovering SensorsThe Siemens TIA Portal (v13) software discovery and configuration protocols are used to discover sensors on a network.1. Start the Siemens TIA Portal (v13) software.2. Click Open an existing project.3. Select a project and open it.4. Click Devices & networks after the project has been uploaded.5. Click Configure networks.VE Series Smart Camera210 www.bannerengineering.com - Tel: 763.544.3164