Workgroup Remote Access Switch 31C ONNECTIVITYConnecting a Workgroup Product to a CSX100 via PPPC ONFIGURATION FOR S ITE “CENTRAL”The configuration on Central to allow IPX Routing to Remote using PPP is as follows:1. Perform initial configuration steps.2. Under Options, select IPX Routing, then:a. Enable IPX Routing.b. Under IPX Internal Network Number enter the following value: 123456.c. Under IPX Interfaces add a LAN Interface and a hexadecimal IPX Network Number(0000BEEF).d. Under IPX Interfaces add a WAN (Remote LAN) Interface and a hexadecimal IPX NetworkNumber (0000BEEF).3. Under Security, select System Options and Information, then under System Information:a. Set your System Name (Central). This matches up with Central device informationconfigured on Remote.b. Set your System Secret (Central_S). This matches up with Central device informationconfigured on Remote.6. Under Security, select Device Level Databases, select On-node Device Entries, then add a devicewhere the Device Name (Remote) must match the system name on Remote. When you add thedevice you must then enter the following information:a. Under ISDN Information select ISDN Line Protocol, then select PPP.b. Under Authentication you must:• Change CHAP Secret so that it matches Remote’s System secret (Remote_S).• Optional: Configure Calling Line Ids (if Calling Line Id security was enabled).c. Under Bridge Information you must make sure that Bridging is enabledC ONFIGURATION FOR SITE “REMOTE”The configuration on Remote to allow IPX Routing from Central using PPP is as follows:1. Start QuickSET and select Custom.ISDNNetwork #0000BEEFFILESER1Node # 0409A0111111IN # 432109*CSX1200Phone # 13135551111IN # 123456*CSX100Phone # 13135552222* IN # = Internal Network Number"Central" "Remote" C A B L E T R O N S Y S T E M SPOWER SERVICE TX RX 10BASE - TLAN B-CHANNELS E1 ONLYB2 B4 B6 B8 B26 B28B22 B24B18 B20B14 B16B10 B12 B30 L1B1 B3 B5 B7 B25 B27B21 B23B17 B19B13 B15B9 B11 B29 B31E1D T1D