Configuration View DescriptionControl ViewConfiguration Views Cabletron Ethernet Hubs4-8 Management Module GuideNetwork AddressThe network IP address (e.g., 132.177.118.24). This field does not appear inthe IRM Control View.This button allows you to reset all of the device’s counters to 0.This button allows you to restart the device.This button allows you to reset the redundancy for the entire hub. This buttonis not available in the IRBM or the IRM Control Views.This button causes the device and all devices connected to it to send Link-uptraps. This button is not available in the IRM, IRM3, or MRXI Control Views.Source Address Age TimeThe number of seconds that a source address is not detected before it isremoved from the source address table. This field does not appear in the IRMor MRXI Control Views.This button controls sending of source address related traps. Possible optionsare TrapsOn and TrapsOff. This button is not available in the IRM or MRXIControl Views.This button indicates whether detection of source addresses on a port that arenot in the source address table will cause the port to be turned off. Possiblestates are LockOff and LockOn. If a port is turned off, an event and alarm willbe generated to warn you of this condition. This button is not available in theIRM or MRXI Control Views.CountersRestart DeviceDevice RedundancyDevice DiscoverSource Address TrapsSource Address Lock