I MECHANICAL SYSTEM IIV. EXPOSURE SYSTEMA. Exposure Assembly1. Detaching the Scanning Lamp1 Disconnect the power plug.2) Detach the copyboard glass.3) Remove the two screws, and detach theanti-glare plate.© Screws © Anti-glare plateFigure 4-554) Push the lamp terminal plate (rear) intothe directionof the arrow, and detach thescanning lamp.© Lamp terminal plate (rear)© Scanning lampFigure 4-56MOtei., 4,,,,,,, -.;,,,, ... c;., „ -- ,, ,. ...', . ..-,-;.- , ••';. ,• 'GQQte;ste^ >•„ - ..,L^/DO/'hot l^^jfi5|ie)^flfe;^iwr'.scanr'ning lamp,ii. Dry wipe the scanning lamp if it issoiled.2. Detaching the Thermal Fuse1) Detach the control panel and the copy-board glass.2) Hold the rear of the No. 1 mirror mount,and move it to the right until it is posi-tioned 'as shown in Figure 4-57.Note:be sure to hold its right side.© Screws (I) No. 1 mirror mount© Thermal fuseFigure 4-573) Remove the two screws, and detach thethermal fuse.4-18 COPYRIGHT© (992 CANON INC. CANON . NP-155OREV.0 JAN. 1992 PRINTED IN JAPAN (IMPRIME AU JAPON]