NOTE:Any of the following error codes may be indicated at time of transmission because of the line condition:##100, ##101, ##102, ##104, ##201, ##280, ##281, ##282, ##283, ##284, ##750,##752, ##754, ##755, ##757, ##759, ##760, ##762, ##764, ##765,##767, ##769, ##770, ##772, ##774, ##775, ##777, ##779, ##780, ##782, ##784,##785, ##787, ##789Any of the following error codes may be indicated at time of reception because of the line condition:##103, ##106, ##107, ##201, ##793##103, ##106, ##107, ##201, ##793● 008: V.34 modulation speed upper limitUse it to set an upper limit to the modulation speed (baud rate) for the V.34 primary channel.● 009: V.34 data speed upper limitUse it to set an upper limit to the data transmission speed for the V.34 primary channel between 2.4K and 33.6K bps in incrementsof 2400 bps. (0: 2.4K to 13:33.6K bps).● 010: Frequency of the pseudo CI signalYou may select a frequency for the pseudo CI signal.Some types of external telephones do not ring when the fax/tel switch-over function is ON.To sound the ring, change the pseudo CI signal#NUMERIC■ Numerical Parameter CompositionNo. Item Range of settings002 RTN transmission condition(1) 1% to 99%003 RTN transmission condition (2) 2 to 99 item004 RTN transmission condition (3) 1 to 99 lines005 NCC pause time length (pre-ID code) 1 to 60 sec006 NCC pause time length (post-ID code) 1 to 60 sec008 Time from Right After Dialing by Auto-dialing to Start of Communication 1 to 65 sec010 line condition identification time length 0 to 9999 (10 msec)011 T.30T1 timer (for reception) 0 to 9999 (10 msec)012 The maximum number of received lines 0 to 65535 (line) * Unlimited in the case of 0013 T.30 EOL timer 500 to 3000 (10 msec)015 hooking detection time length 0 to 999016 time length to first response at time of fax/tel switchover 0 to 9017 pseudo RBT signal pattern ON time length 0 to 999018 pseudo RBT signal pattern OFF time length (short) 0 to 999019 pseudo RBT signal pattern OFF time length (long) 0 to 999020 pseudo CI signal pattern ON time length 0 to 999021 pseudo CI signal pattern OFF time length (short) 0 to 999022 pseudo CI signal pattern OFF time length (long) 0 to 999023 CNG detection level at time of fax/tel switchover 0 to 7024 pseudo RBT transmission level at time of fax/tel switchover 10 to 200 to 20 (120/230V)025 Answering machine connection function signal detection time 0 to 999027 preamble detection time length for V21 low-speed flag 20 (x 10ms)051 Hooking detection threshold 0 to 655035053 Setting of DTMF call origination count at remote reception of fax 0 to 65535 (25 counts)054 Setting of busy tone output time when handset is used 0 to 480 (60min) (0: no data acquisition)055 acquisition period of environmental log data 0 to 480 (60min)056 display the type of soft counter 1 101 (Fixed)8. Service Mode239