● #SCAN> READER> ADJUST> ADJ-XY> ADJ-XAdjustment of scanning system image lead edge position (image's scan-start position in vertical scanning direction)0.1mm shift of image scan-start position toward the trail edge direction by 1-increment in the setting.NOTE:Be sure to enter the value on service label when replacing the CCD unit.If changing the setting value of this item, be sure to Note the changed value on the service label.● #SCAN> READER> ADJUST> ADJ-XY> ADJ-YAdjustment value of image scan-start position 0.1mm shift of image scan-start position toward the trail edge direction by 1-increment in the setting.NOTE:Be sure to enter the value on service label when replacing the CCD unit.If changing the setting value of this item, be sure to Note the changed value on the service label.● #SCAN> READER> ADJUST> ADJ-XY> ADJ-SAdjustment of CCD/CIS scan-start cell position (image scan-start position in horizontal scanning direction)Adjust the position to measure data for shading correction with standard white plate. This item must not be normally used.NOTE:Be sure to enter the value on service label when replacing the CCD unit.If changing the setting value of this item, be sure to Note the changed value on the service label.● #SCAN> READER> ADJUST> ADJ-XY> ADJ-Y-DFAdjustment of horizontal scanning position at feeder mode.0.1mm shift of image scan-start position toward the front direction by 1-increment in the setting value.NOTE:Be sure to enter the value on service label when replacing the CCD unit.If changing the setting value of this item, be sure to Note the changed value on the service label.● #SCAN> READER> ADJUST> ADJ-XY> ADJ-Y-POSAdjustment of CCD/CIS scan position at stream-reading mode with DF.This item must not be normally used.NOTE:Be sure to enter the value on service label when executing RAM clear of the reader controller PCB/ replacing the reader controllerPCB.If changing the setting value of this item, be sure to Note the changed value on the reader's service label.● #SCAN> READER> ADJUST> ADJ-XY> ADJ-X-MGFine adjustment of magnification ration in vertical scanning when scanning with reader copyboardExecute fine adjustment of vertical scanning magnification ratio when scanning with reader copyboard.0.1mm shift of image scan-start position toward the front direction by 1-increment in the setting value.NOTE:Be sure to enter the value on service label when replacing the CCD unit.If changing the setting value of this item, be sure to Note the changed value on the service label.● #SCAN> READER> ADJUST> CCD> W-PLT-XWhite label data entry with standard white plateThis item must not be normally used.8. Service Mode256