PARAMETER MENU SOFTKEY TABLE SCREEN NAME CONFIGURABLETarget Guide Vane Pos STATUS COMPRESS XTarget Guide Vane Pos SERVICE CONTROL ALGORITHM STATUS CAPACITYTarget VFD Speed STATUS COMPRESS XTarget VFD Speed STATUS STARTUPTarget VFD Speed SERVICE CONTROL ALGORITHM STATUS CAPACITYTemp Pulldown Deg/Min. SERVICE EQUIPMENT SERVICE TEMP_CTL XTemperature Reset STATUS MAINSTATTemperature Reset SERVICE EQUIPMENT SERVICE TEMP_CTLTerminate Lockout SERVICE EQUIPMENT SERVICE CONTROL TEST XThermistors Control Test SERVICE CONTROL TESTTIME AND DATE SERVICE TIME AND DATETime Broadcast Enable SERVICE EQUIPMENT CONFIGURATION BRODEFTorque Current STATUS POWERTorque Current SERVICE CONTROL ALGORITHM STATUS VFD_HISTTotal Compressor Starts STATUS MAINSTATTotal Error + Resets SERVICE CONTROL ALGORITHM STATUS CAPACITYTower Fan High Setpoint SETPOINT SETPOINT XTower Fan Relay High STATUS STARTUPTower Fan Relay High Test SERVICE CONTROL TEST DISCRETE OUTPUTS XTower Fan Relay Low STATUS STARTUPTower Fan Relay Low Test SERVICE CONTROL TEST DISCRETE OUTPUTS XTransducer Voltage Ref SERVICE CONTROL TEST PRESSURE TRANSDUCERSUS Imp / Metric SERVICE ICVC CONFIGURATION XValues at Last Fault: SERVICE CONTROL ALGORITHM STATUS VFD_HISTVFD Checksum Error STATUS VFD_STATVFD Cold Plate Temp STATUS POWERVFD Cold Plate Temp SERVICE CONTROL ALGORITHM STATUS VFD_HISTVFD Comm Fault STATUS VFD_STATVFD CONFIG PASSWORD SERVICE VFD CONFIG DATA XVFD Coolant Flow STATUS HEAT_EXVFD Coolant Flow STATUS POWERVFD Coolant Solenoid Test SERVICE CONTROL TEST DISCRETE OUTPUTS XVFD Enclosure Temp STATUS POWERVFD Enclosure temp SERVICE CONTROL ALGORITHM STATUS VFD_HISTVFD Fault STATUS VFD_STATVFD Fault Code STATUS VFD_STATVFD Fault Code SERVICE CONTROL ALGORITHM STATUS VFD_HISTVFD FAULT HISTORY SERVICE CONTROL ALGORITHM STATUS VFD_HISTVFD Gain SERVICE EQUIPMENT SERVICE SETUP2 XVFD Gateway Version # STATUS VFD_STATVFD Increase Step SERVICE EQUIPMENT SERVICE SETUP2 XVFD Inverter Version # STATUS VFD_STATVFD Maximum Speed SERVICE EQUIPMENT SERVICE SETUP2 XVFD Minimum Speed SERVICE EQUIPMENT SERVICE SETUP2 XVFD Power On Reset STATUS VFD_STATVFD Rectifier Version # STATUS VFD_STATVFD Speed Control SERVICE EQUIPMENT SERVICE SETUP2VFD Start STATUS STARTUPVFD Start Inhibit STATUS VFD_STATWater Flow Verify Time SERVICE EQUIPMENT SERVICE SETUP1 XWSM Active? SERVICE CONTROL ALGORITHM STATUS WSMDEFMEOrder No: 11990-76, 10.2009 - Supersedes order No: New Manufacturer: Carrier SCS, Montluel, France.Manufacturer reserves the right to change any product specifications without notice. Printed in the Netherlands.