62-61753-213-19* Displays information or setting entered in the microprocessor Configurations+ May or may not be displayed depending on Parameter/Configuration settingsDATA DEFINITION*+PRODUCTSHIELD SETUP: This will only display when IntelliSet is installed, ProductShield setting is ONand ECONO, HIGH AIR and/or WINTER is/are NOT OFF.• PRODUCTSHIELDECONO:Displays ProductShield Econo setting (OFF, Go To Start-Stop OR Go ToContinuous Run•• ECONO MIN TEMP Displays minimum temperature setting for activation of ProductShield Econo.(Will only be displayed if Econo is NOT OFF)•• ECONO MAX TEMP Displays maximum temperature setting for activation of ProductShield Econo.(Will only be displayed if Econo is NOT OFF)•• ECONO DELTA-T Displays Delta-T setting for activation of ProductShield Econo. (Will only bedisplayed if Econo is NOT OFF)• PRODUCTSHIELD HIGHAIR:Indicates if Product Shield High Air is ON or OFF•• HIGH AIR MIN TEMP Displays minimum ambient temperature setting for activation of ProductShieldHigh Air (Will only be displayed if High Air is ON)•• HIGH AIR MAX TEMP Displays maximum temperature setting for activation of ProductShield High Air(Will only be displayed if High Air is ON)•• HIGH AIR DELTA-T Displays Delta-T setting for activation of ProductShield High Air (Will only bedisplayed if High Air is ON)• PRODUCTSHIELD:WINTER - xx°Indicates the ambient temperature below which ProductShield Winter will beactive (Will only be displayed if WINTER is NOT OFF)*+RANGE 1 LOCK This is only displayed when Range Lock 1 is configured ON.Displays Range Lock 1 setting:OFF = Temperature Range 1 Lock is turned off.CONTINUOUS = When the set point is set between Range 1 Minimum & Max-imum Temperatures, the unit is set to operate only in Continuous.START-STOP - When the set point is set between Range 1 Minimum & Maxi-mum Temperatures, the unit is set to operate only in Start-Stop.*+•RANGE 1 MINIMUM TEMP Displays minimum temperature setting for Range 1. (Will only be displayed ifRange Lock 1 is ON)*+•RANGE 1 MAXIMUM TEMP Displays maximum temperature setting for Range 1. (Will only be displayed ifRange Lock 1 is ON)*+RANGE 2 LOCK This is only displayed when Range Lock 1 is configured ON.Displays Range Lock 1 setting:OFF = Temperature Range 2 Lock is turned off.CONTINUOUS = When the set point is set between Range 2 Minimum & Max-imum Temperatures, the unit is set to operate only in Continuous Run/.START-STOP = When the set point is set between Range 2 Minimum & Max-imum Temperatures, the unit is set to operate only in Start-Stop.*+•RANGE 2 MIN. TEMP Displays minimum temperature setting for Range 2. (Will only be displayed ifRange Lock 2 is ON)*+•RANGE 2 MAX. TEMP Displays maximum temperature setting for Range 2. (Will only be displayed ifRange Lock 2 is ON)*+TEMPERATURE (REMOTE)SENSOR 1 (or 2 or 3)Will only display when one or more of the optional sensors are configured ON.Displays temperate reading of remote Temperature Sensor 1 (or 2 or 3).