Alarm Control Panel User Manual22After the Forced Arming has been set, the bypass LED indicator lights up showing that some detectors areautomatically bypassed. If the Forced Arming is set for the whole Area, a lower case t is shown on the LCDdisplay, see Figure 3-8. The Forced Arming could inhibit sensors that you DID NOT wish to bypass from arming without yourrealizing it. After disarming, all the detectors involved in the Forced Arming will become available for arming again.Forced armingFigure 3-83.1.6 Rapid ArmingRapid Arming allows you to Arm the alarm system without entering the user code. The only differencebetween Rapid Arming and arming with the code is the practicality of performing the operation quickly. ToDisarm the system, you must type in a valid code.PreparationTo use the Rapid Arming, the TECHNICIAN must have programmed the Keypad. Otherwise, the Keypadcannot do the Rapid Arming.ProcedureTo do the Rapid Arming, press and hold for the arming that you require on the Areas that belong tothe Keypad. You can also arm the system with IMMEDIATE or DELAYED exit time for Rapid Arming if this isprogrammed by the TECHNICIAN. To disarm from Rapid Arming, you need to type in a valid user code.3.1.7 Arming through TimerYou can arm the alarm system by timer that is set on the SYSTEM TIMER menu.This setting can be managed and programed by the TECHNICIAN, Supervisor, and Manager. For details,see "4.10 SYSTEM TIMERS" menu.The system also supports programming HOLIDAYS during which the TIMER will not have any effect. Fordetails, see "4.12 HOLIDAY" menu.3.1.8 Arming from RemoteThe alarm system can also be armed from telephone through a specific procedure with an interactive vocalguide or through SMS messages.