Alarm Control Panel User Manual27Press to confirm the setting, and then press to return to the SYSTEM TROUBLESStep 3menu.Then you can press and to move to the next menu or press to exit from the UserMenu.ZONE MANAGER4.3The ZONES MANAGER menu allows any Zone of the system to be placed in BYPASS regardless of itscurrent status (open or trouble).Type in the access code, and then press .Step 1The ZONE TROUBLE menu is shown on the LCD display (Figure 4-1).Press and to scroll up and down until you reach the ZONE MANAGER menu, and thenStep 2press .The ZONE MANAGER menu is shown on the LCD display. See Figure 4-5.Zone managerFigure 4-5Press and to select the desired Zone, and then press .Step 3The submenu for changing status is shown.Press and to select the status for the desired Zone.Step 4 ACTIVE: The Zone is in normal condition. ISOLATE: The Zone is excluded permanently and can be brought back only when switching toACTIVE. TEST: The Zone is temporarily excluded for a period that is defined by the TECHNICIAN, andthe Zone continues to be part of the armed Zones but do not generate alarms.TEST mode is not applicable to the type Entry 1 delay and Entry 2 delay. BYPASSED: The Zone is temporarily bypassed from arming of the system. The Zone can bere-armed when the Area is disarmed.Press to confirm the setting, and then press to return to the wired zones selectionStep 5menu.