8.3.4 Motor connector with shieldplateThe motor is connected to the SERVOSTAR 600 by a Power Combicon connector (X9). You canobtain the connector kit from us (connector, housing, shield plate, rubber bushes, installation mate-rial, order codes see p.117).The cable material depends on the motor that is used. Please refer to the installation manual for thecorresponding motor series. Please take note that the connector can accept a maximum conductorcross-section of 4mm².First push the rubber sleeve onto thecable, and then strip off about 70mmof the outer covering, without damag-ing the shielding.Carefully separate the shielding braidfrom the cores.Twist the shielding braid into a pigtailand tie it to the sleeve with the wire.Shorten the brake cores to 55mmand the power cores to 45mm.Fold back the overhanging length ofthe shielding pigtail to face forwards.Strip off the ends of the cores forabout 10mm. This length can vary,depending on the type of bootlaceferrule that is used.Apply bootlace ferrules to the con-ductors. Place the shield plate in thebottom half of the connector housing.Place the cable in the strain relief, sothat the folded shielding pigtail lies onthe shield plate, but the tie-wire is notclamped inside.Tighten up the screws, without crush-ing the cable.Place the connector in the housing.Take care that the tongue of theshield plate sits in the PE clamp.Wire up the connector according tothe wiring diagram on page 50, andtighten up the clamping screws. Takecare that the insulation is not trappedunderneath. Close the housing.SERVOSTAR ® 601...620 Product Manual 43Danaher Motion 07/2007 Electrical Installation