Danaher Motion 05/2008 SpecificationsS200-VTS Product Manual 133.2.5 AC Control Power Inrush Current & FusingWorse Case Inrush Peak Current at 240 VAC 10 A 0-pInrush Pulse Width 1.60 msFusing – Control Inputs Bussmann MDA – 1/2Nominal Power draw Base: 7 WWith Option Card: 10 W3.2.6 AC Power On DelayControl Power Applied to Drive Operational 1.25 secondsBus Power To Full Bus On Soft Start Units 1.0 seconds3.3 DC Input Drives - Control and Power3.3.1 DC Control Power SupplyControl Voltage Range (VDC)(J1-1 to J1-2)+10 to +90Control Input Power (watts)1 2 to 81(20 watt min supply recommended) Refer to the DC Power Supply Sectionfor detailed application information and requirements.3.3.2 DC Bus Voltage and Faults+BUS Voltage Range (VDC) (J1-3 to J1-2) +20 to +90+BUS Undervoltage Fault +17 VDC nominal+BUS Overvoltage Fault +91 VDC nominal3.3.3 DC Control Power On DelayControl Power Applied to Drive Operational 1.5 seconds3.4 Motor Current ControlMotor Phase Current Waveform(In Sine or six-step mode output torque = MotorKT *Drive IFB )Pure sinusoidal or six-step,depending on feedbackdeviceMotor Shaft Torque (Ignoring motor magnetic saturation)Peak (hot motor winding)Multiply KT by 1.06 for cold motor winding (AKMor PMA motors).KT (N-m/ARMS)*DriveIpeak (ARMS)Instantaneous KT (N-m/ARMS)*IFB(ARMS)