Danaher Motion 05/2008 Basic ConfigurationS200-VTS Product Manual 677.1.2 S1 - Rotary Setup SwitchSwitch S1 is a 10-position rotary switch. The function of switch S1 depends on the feedbackmode in which the drive is configured.7.1.2.1 S1 Function with SFD FeedbackWhen using the Smart Feedback Device (SFD), S1 sets the emulated encoder line count.S1PositionEmulated EncoderLines/Revolution S1 Position Emulated EncoderLines/Revolution0 User settable1(factory default = 500) 5 20481 512 6 40962 1000 7 50003 1024 8 81924 2000 9 100001S1 position 0 allows setting the non-volatile line count via the driveparameter EncOut to any of the following values:128, 512, 1024, 2048, 4096, 8192, 16384, 32768125, 500, 1000, 2000, 2500, 5000, 10000, 20000The value written replaces the factory default value listed in position 0 ofthe table.NOTEThe emulated encoder output is only available when usingSFD feedback to the base unit or a high-resolution feedbackdevice connected to the option card.