– The server slot is empty, or the server in the slot is turned off.– The VA is unmapped from a server or a slot.– All affected servers are powered off.• Virtual disks are created and they are assigned as Virtual Adapter 1, Virtual Adapter 2, Virtual Adapter 3, or Virtual Adapter 4.For more information, see Applying Virtual Adapter Access Policy to Virtual Disks.NOTE:• You can map only one virtual adapter to one server at a time.• Without an appropriate license, you can unmap a VA–server assignment, or map the VA to the default serve, only.• The default mapping is VA1–Server Slot 1, VA2–Server Slot 2, VA3–Server Slot 3, and VA4–Server Slot 4.• If full height server is inserted, then the upper slot has the VA mapped to it while the bottom slot is still unmapped. Forexample, a full height in slot 1 has VA1 assigned to slot 1 and VA3 is still unmapped.• If the system has an enterprise license, then you can assign any one of the four VAs to a server slot. However, you can stillmap one virtual adapter to one server at a time.• Virtual adapter rules are applied to the external and integrated shared storage adapters.To map or unmap a virtual adapter from a server slot:1. In the left pane, click Chassis Overview → Storage → Setup → Virtualization.The Storage Virtualization page is displayed.2. To select the required type of assignment, from the Assignment Mode: Virtual Disks to Virtual Adapters table, select:• Single Assignment — Select to assign one virtual disk to one virtual adapter.• Multiple Assignment — Select to assign a virtual disk to multiple virtual adapters. Read the on-screen instructions beforeselecting this option.NOTE: Select the Multiple Assignment mode only when the servers have Cluster Services installed on them. Use ofthis mode without Cluster Services may lead to corrupted or lost data.NOTE: You can assign a virtual disk to multiple virtual adapters from CMC CLI even when the Assignment Mode isset to Single Assignment in the CMC web interface.3. In the Virtual Adapters Mapped table, from the Action drop-down list, select one of the following options, and then click Apply.• — Select the slot to which the VA must be assigned.• Unmap — Select to remove the VA assignment to a slot.The VA is mapped or unmapped from the selected server slot, based on the selected action.NOTE: Consider a VA assigned to server in the lower slot (3 or 4). When a half height server (slot 3 or 4) is replacedwith a full height server, the full height server does not access the VA assigned to lower slots. Inserting a half heightserver again, provides access to the VA.Map or un-map a PERC Virtual Controller to blade:• Each External Shared PERC 8 card has four virtual adapters (VA). If one or two External Shared PERC 8 cards are presentin the system, then in shared mode you can map or un-map one of the four virtual adapters’.• If an external PCIE slot is occupied by shared adapter, the virtual adapter mapping can get the current details or informationfor VA mapping of the shared storage VA pool.• Shared device is not supported when the external PCIE slot is occupied by a shared adapter. Using the shared adapter, youcan support shared device by changing the shared storage VA pool.Fault-Tolerance in Storage ControllersHigh Availability (HA) in storage enables availability of multiple integrated components and multiple access points to storageresources. In case a storage component stops functioning, the server is supported by a second critical component or path to theavailable data. High Availability only minimizes downtime by restoring services behind the scenes, in most cases before the non-169