NOTE:• Error is displayed if you enter an invalid value.• Initially the value which is saved in the firmware is displayed.• You must have Chassis Configuration Privileges to set asset tag and asset name of the enclosure.Setting the Temperature Warning Threshold of the Enclosure Using Web InterfaceTo set temperature warning threshold of the enclosure:Click Chassis Overview → Storage → Enclosures → Setup. Select the enclosure from the Enclosure drop-down menu, then enterthe appropriate values for minimum and maximum for warning threshold temperatures of temp sensor 2 and 3. Type the Asset tagand Asset name in the appropriate fields, and then click Apply. For more information, see the CMC Online Help.Setting Temperature Warning Threshold of the Enclosure Using RACADMTo set the minimum warning threshold of temperature probe in the enclosure, use racadm raid settempprobes:TempSensor.Embedded.0:Enclosure.External.1-0:RAID.ChassisSlot.6-1 –pMinimumWarningThreshold command.To set the maximum warning threshold of temperature probe in the enclosure, use racadm raid settempprobes:TempSensor.Embedded.0:Enclosure.External.1-0:RAID.ChassisSlot.6-1 –pMaximumWarningThreshold command.For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guideavailable at dell.com/support/manuals.Viewing Fan Status and attributes of the EnclosureFan status and attributes displays the status of the enclosure fan and contains a status value that is unique from the enclosure. Youcan have up to two fans, and the enclosure firmware creates a status for each fan. You must have CMC Login privileges to view fanstatus.NOTE: If a PSU is missing, the corresponding fan of the PSU displays a critical status.Viewing Fan Status and attributes of the Enclosure Using Web InterfaceTo view the status and attributes of PSU:Click Chassis Overview → Storage → Enclosures → Properties. The Enclosure Page provides the health status and attributes forthe fan of the enclosure. Expand the external enclosure to view the status for the fan of the enclosure. For more information, seethe CMC Online Help.Viewing Fan Status and attributes of the Enclosure Using RACADMTo view the status of fan, use racadm raid get fans -o -p Status command.To view the attributes of fan, use racadm raid get fans -o command.For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guideavailable at dell.com/support/manuals.Viewing Enclosure Properties Using CMC Web InterfaceTo view the enclosure properties:1. In the left pane, click Chassis Overview → Storage → Enclosures → Properties.2. On the Properties page, under the Enclosure section, click the to get a graphical view of the physical disk drives and theirstates, summary of physical disk drive slots, and advanced properties.182