show sflow interface interface-nameExamples of the sFlow show CommandsThe following example shows the show sflow interface command.Dell#show sflow interface tengigabitethernet 1/1Te 1/1sFlow type :IngressConfigured sampling rate :16384Actual sampling rate :16384Counter polling interval :20Extended max header size :128Samples rcvd from h/w :0The following example shows the show running-config interface command.Dell#show running-config interface tengigabitethernet 1/16!interface TenGigabitEthernet 1/16no ip addressmtu 9252ip mtu 9234switchportsflow ingress-enablesflow sample-rate 8192no shutdownDisplaying Show sFlow on a Stack-unitTo view sFlow statistics on a specified stack-unit, use the following command.• Display sFlow configuration information and statistics on the specified interface.EXEC modeshow sflow stack—unit slot-numberExample of Viewing sFlow Configuration (Line Card)Dell#show sflow stack-unit 1stack-unit 1Samples rcvd from h/w :165Samples dropped for sub-sampling :69Total UDP packets exported :77UDP packets exported via RPM :77UDP packets dropped :Configuring Specify CollectorsThe sflow collector command allows identification of sFlow collectors to which sFlow datagrams are forwarded.You can specify up to two sFlow collectors. If you specify two collectors, the samples are sent to both.• Identify sFlow collectors to which sFlow datagrams are forwarded.CONFIGURATION modesflow collector ip-address agent-addr ip-address [number [max-datagram-size number] ] |[max-datagram-size number ]The default UDP port is 6343.The default max-datagram-size is 1400.684 sFlow