rising-thresholdSyntax rising-threshold percentage;Hierarchy Level [edit snmp health-monitor]Release Information Statement introduced before Junos OS Release 10.2 for J-EX Series switches.Description The upper threshold is expressed as a percentage of the maximum possible value forthe sampled variable. When the current sampled value is greater than or equal to thisthreshold, and the value at the last sampling interval is less than this threshold, a singleevent is generated. A single event is also generated if the first sample after this entrybecomes valid is greater than or equal to this threshold. After a rising event is generated,another rising event cannot be generated until the sampled value falls below this thresholdand reaches the falling-threshold.Options percentage—The lower threshold for the alarm entry.Range: 1 through 100Default: 80 percent of the maximum possible valueRequired PrivilegeLevelsnmp—To view this statement in the configuration.snmp-control—To add this statement to the configuration.RelatedDocumentation• falling-threshold on page 3327• Configuring the Falling Threshold or Rising Threshold3344Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS