Configuring power buttonTo configure the chassis power button:1. In the left pane, click Chassis Overview → Front Panel → Setup.2. On the Front Panel Configuration page, under the Power Button Configuration section, select the Disable Chassis PowerButton option, and then click Apply.The chassis power button is disabled.Accessing a server using KVMTo map a Server to KVM from web interface:1. Connect a monitor to the video connector and a keyboard to USB connector located on the front of the chassis.2. In the left pane, click Chassis Overview → Front Panel → Setup.3. On the Front Panel Configuration page, under the KVM Configuration section, select Enable KVM Mapping option.4. On the Front Panel Configuration page, under the KVM Configuration section, for KVM Mapped option, select the desiredserver from the drop down list.5. Click Apply.To map a Server to KVM using racadm, useracadm config -g cfgKVMInfo -o cfgKvmMapping [server slot #]command.To view the current KVM mapping using racadm, use racadm getconfig -g cfgKVMInfo.Configuring chassis management at server modeThis feature allows you to manage and monitor the chassis shared components and chassis nodes as rack servers. When thisfeature is enabled, you can use the iDRAC RACADM proxy, blade server operating systems and Lifecycle Controller to do thefollowing:• Monitor and manage chassis fans, power supplies, temperature sensors• Update and configure the CMC firmwareConfiguring chassis management at server using CMC web interfaceTo enable chassis management at server mode:1. In the left pane, click Chassis Overview → Setup → General.2. In the General Chassis Settings page, from the Chassis Management at Server Mode drop-down, select one of the followingmodes:• None — This mode does not enable you to monitor or manage the chassis component through iDRAC, OS, or LifecycleController.• Monitor — This mode enables you to monitor the chassis components but you cannot perform any firmware updatethrough iDRAC, OS, iDRAC RACADM proxy, or Lifecycle Controller.• Manage and Monitor — This mode enables you to monitor the chassis components and update the CMC firmware usingDUP through iDRAC, OS, iDRAC RACADM, or Lifecycle Controller.Configuring chassis management at server mode using RACADMTo enable the Chassis Management at server using RACADM, use the following commands:• To disable Chassis Management at Server mode, use:racadm config –g cfgRacTuning – cfgRacTuneChassisMgmtAtServer 0• To change Chassis Management at Server mode to monitor, use:racadm config –g cfgRacTuning – cfgRacTuneChassisMgmtAtServer 131