3. Under Components, select one of the following options:• Split Dual Host• Split Single Host• JoinedNOTE: Power off the compute sled before configuring the storage sled. Click Server Power Control at the top ofthe page to power off the compute sled. For more information, see the Online Help.4. Click Apply.Configuring storage sleds using RACADMYou can connect storage sleds with compute sleds using the config or getconfig RACADM command with thecfgStorageModule option. For more information, see the getstoragemoduleinfo section in the Chassis Management Controllerfor PowerEdge FX2/FX2s RACADM Command Line Reference Guide available at dell.com/support/manuals.Managing storage sleds using iDRAC RACADM proxyThe iDRAC RACADM proxy feature enables you to manage storage sleds in the FX2s chassis through iDRAC RACADM, when CMCis not in the network.To access iDRAC locally, use the following command:racadm --proxyExample: racadm getractime --proxyYou can also access the iDRAC RACADM remotely. For more information, see the section, “RACADM Proxy”, in the Integrated DellRemote Access Controller 8 (iDRAC8) Version 2.10.10.10 RACADM Command Line Interface Reference Guide.NOTE: Only local and remote RACADM proxies are supported in this release.Viewing storage array statusIn the left pane, click Chassis Overview → Server Overview → . The Storage Array Status page is displayed in theright pane. You can also access the Storage Array Status page from the Chassis Health page.1. On the Chassis Health page, click a storage sled on the front panel image.The details of the storage sled are displayed at the bottom of the right pane.2. Under Quick Links, click Storage Array Status.For more information, see the Online Help.92