Product informationCBC-8000 capacitor bank control installation and operation instructions MN916001EN—October 2018 Eaton.com 1Product informationIntroductionThis document provides installation and operationinstructions for the CBC-8000 capacitor bank control.Refer to the following documents for additional information: CBC-8000 capacitor bank control ProView NXG applicationsoftware programming guide (MN916002EN) CBC-8000 capacitor bank control communications userguide (MN916003EN) Communications Point Data Base (TD916002EN) CBC-8000 control ordering guide (CA916001EN) CBC-8000 control reference guide (B1160-11041)Read this manual firstRead and understand the contents of this manual and followall locally approved procedures and safety practices beforeinstalling or operating this equipment.Additional informationThese instructions cannot cover all details or variations in theequipment, procedures, or processes described, nor providedirections for meeting every possible contingency duringinstallation, operation, or maintenance. When additionalinformation is needed to satisfy a problem not coveredsufficiently for the user's purpose, contact your local Eaton’sCooper Power® series customer service representative.Compliance standardsThe CBC-8000 control is designed and tested in accordancewith applicable sections of the following standards:• IEC 61000-4-2 Electrostatic discharge• IEC 61000-4-4 Electrical fast transient• IEC 61000-4-5 Combination surge• IEC 61000-4-11 Dip and interrupts• IEC 61000-4-12 Ring/oscillatory wave• IEC 61000-2-27 Mechanical shock• FCC 15 Part BThe CBC-8000 control enclosure is rated NEMA 4X rain-tightwhen it is mounted vertically and the door latch is tighteneddown to compress the door’s neoprene rubber gasket.Acceptance and initial inspectionEach CBC-8000 control is completely assembled, tested andinspected at the factory. It is carefully calibrated, adjustedand in good condition when accepted by the carrier forshipment.Upon receipt, inspect the carton for signs of damage. Unpackthe control and inspect it thoroughly for damage incurredduring shipment. If damage is discovered, file a claim withthe carrier immediately.Handling and storageBe careful during handling and storage of the CBC-8000control to minimize the possibility of damage. If the control isto be stored for any length of time prior to installation,provide a clean, dry storage area.Note: There are several wiring configurations available forthe CBC-8000 control. Apply AC power to the controlas defined by your order number. Refer to Installingthe control on Page 20 in this manual.Control specificationsThe CBC-8000 control specifications are listed below.Table 1. CBC-8000 control specificationsSpec ValueTemperature range -40° F to 185° F (-40° C to 85° C)Relative humidity 5% to 95% non-condensingPower requirements 85 to 265 VAC; 50 Hz or 60 HzMaximum wattage CBC-8000 control – 1 RS-232 SelectComm module:2.5 W @ 120 VAC3.1 W @ 240 VACCBC-8000 control – 1 Power Over Ethernet SelectCommmodule:3.1 W @ 120 VAC3.7 W @ 240 VACOutputs Type 1 Form C contacts interlocked and wired as twoForm A outputsInputs Seven sensor inputs for control or monitoring;0 - 10 VACProtocol DNP3 Level 2Communications Two-Way SelectComm module:RS-232 serial portEthernet portWi-Fi portSize 12.21” W x 13.93” H x 7.5” D(31 cm W x 35.38 cm H x 19.05 cm D)Weight 9 lbs (4.08 kg) without mounting hardwareEnclosure Meets or exceeds UL 746C ultraviolet light exposureand water resistance testingFuse rating Eaton fuse style FNM-10 (10 A)