CBC-8000 capacitor bank control descriptionCBC-8000 capacitor bank control installation and operation instructions MN916001EN—October 2018 Eaton.com 3Door latchThe door latches for the CBC-8000 control allow the door tobe secured with 3/8 inch (1.905 cm) ring padlocks. The doorlatches will accommodate both the Sterling SecuritySystems Junior and Senior series padlocks.Each enclosure contains two single-loop, latches that are SaltFog Test ASTM B117 and NEMA 4X rated.Door holdThe optional open door hold kit prevents the door swing thatcan occur in field maintenance situations. The open door holdwill securely hold the door in a fixed, open position while anoperator is accessing the HMI front panel.The open door hold kit can be ordered for new controls or itcan be installed as a field retrofit for existing controls.Figure 2. CBC-8000 control open door holdJaws meter baseThe distance between the back of the enclosure and thejaws was increased to provide more room for installing andsecuring the meter socket ring. An additional 1/2 inch(1.27 cm) was added between the back of the pole mountenclosure and the jaws.Ground lugThe ground lug for controls manufactured after October 2016will accommodate a 2 AWG pole ground wire.Cable security sleeveAn optional cable security sleeve is available to securelyterminate the cabling that enters the bottom of theenclosure. Adding a cable security sleeve to your control willhelp prevent unauthorized personnel from disconnecting theDIN connector and cable.The cable security sleeve can be ordered as an option to besupplied with new controls or it can be installed as a fieldretrofit for existing controls.Note: Security sleeves ordered with new controls are notinstalled at the factory. This option must be installedby the customer.Figure 3. Cable security sleeveFront panelThe CBC-8000 control front panel is illustrated in Figure 4 onpage 4.The front panel is separated into two clearly identified, color-coded sections:• Programming panel – The top portion of the front panel isused for programming the control and providing LEDstatus indication.• Operating panel – The lower portion of the front panel isused for operating the control and capacitor bank.The control includes a Power Save feature that will turn offthe backlit LCD display after 5 minutes of inactivity at thefront panel (no buttons pressed). Pressing any button on thefront panel will turn the LCD backlight on.The control also includes a Reset Menu feature that willcause the LCD display to revert to the root menu after 5minutes of inactivity.