404. Primary OperationEaton Electric General Inverters DF1 Series UMXXXXXXXXE February 2020 www.eaton.com4.2 Operation modes of the inverter• The operation modes are related to the reference source of the target frequency and the signal source of the motorstarting. The Eaton DF1 inverter has a total of ten kinds of operation modes,namely, “PU mode ”, “JOG mode”, “external mode ”, ”communication mode ”, “combined mode 1 ”, ”combined mode 2 ”, “com-bined mode 3 ”, “combined mode 4 ” and “combined mode 5 ” and the second operation mode.• You can use parameter unit to monitor the output frequency, the output voltage and the output current, as well as toview the alarm message, the parameter setting and the frequency setting. The operator has four work modes, namely,“operation mode”, “monitoring mode”, “frequency setting mode” and “parameter setting mode”.• When 00-16(P.79)=0, the external mode ( ) is the default mode after the inverter is turned on. Use 00-16(P.79)to switch the operation mode.Relatedparameters Values Operation mode The reference source of target frequency The signal source ofmotor starting RemarksOperationmodeselection00-16 (P.79)0PU mode ( ) PU parameter unit or but-ton for PU parameterunitThe “PU mode”,“JOG mode” and“external mode”are interchange-able.JOG mode ( ) The setting value of 01-13 (P.15) or but-ton for PU parameterunitExternal mode( )“External voltage/current signal”, “combination ofmulti-speed stage levels” and external JOG (01-13(P.15)) External forward andreverse terminalsFrequency given by (03-09 (P.550))Frequency of each section in the programmedoperation mode 04-19~ 04-26 /P.131~P.138 External STF terminal1PU mode ( ) Equal to the “PU mode” when 00-16 (P.79)=0 The “PU mode”and “JOG mode”are interchange-able.JOG mode ( ) Equal to the “PU mode” when 00-16 (P.79)=02 External mode( ) Equal to the “External mode” when00-16 (P.79)=03 Communicationmode ( ) Communication Communication4 Combined mode 1( ) PU parameter unit External forward andreverse terminals5 Combined mode 2( )“External voltage / current signal”, “combinationof multi-speed stage levels”, frequency given bypulse(03-09(P.550))or but-ton for PU parameterunit6 Combined mode 3( )Communication, “combination of multi-speed stagelevels” and External JOG(01-13(P.15))External forward andreverse terminals7 Combined mode 4( )“External voltage / current signal”, “combinationof multi-speed stage levels”, frequency given bypulse (03-09(P.550))Communication8 Combined mode 5( )PU operation panl, “combination of multi-speedstage levels” and External JOG (01-13(P.15))External forward andreverse terminals99999 Second operationmode ( ) Sets by 00-17 (P.97) Sets by 00-18(P.109)FWD REVFWD REVFWD REV