555. Parameter DescriptionEaton Electric General Inverters DF1 Series UMXXXXXXXXE February 2020 www.eaton.com5.1.3 Parameter protection• Whether to enable the writing to various parameters or not can be selected. Use this function to prevent parameter-values from being rewritten by misoperation.•Parameter writeprotection selection• Writing parameters only during stop(00-03=“0”initial value)Exception During operation, the parameters below can be written:Parameter Name FactoryValue Setting Range Content00-03P.77Selection ofparameters writeprotection00 Parameters can be written only when the motor stops.1 Parameters cannot be written.2 Parameters can also be written when the motor is running.3 Parameters cannot be written when in password protection.00-04P.294 Decryption parameter 0 0~65535 Write the registered password to decrypt the parameter protection.00-05P.295 Password setup 0 0~65535 Register password for parameter protection setting.Group No. Name Group No. Name00-03 P.77 Selection ofparameters write protection 02-25 P.198 The minimum input current/voltage of AI300-07 P.161 Multi-function display 02-26 P.199 The maximum input current/voltage of AI302-04 P.54 Function of terminal AO1 output 02-27 P.196 The percentage corresponding to theminimum input current/voltage of AI302-05 P.537 Function of terminal AO2 output02-12 P.192 The minimum input positive voltage of AI1 02-28 P.197 The percentage corresponding to themaximum input current/voltage of AI302-13 P.193 The maximum input positive voltage of AI102-14 P.194 The percentage corresponding to the mini-mum positive voltage of terminal AI102-34 P.548 The minimum input current/voltage of AI202-35 P.549 The maximum input current/voltage of AI202-15 P.195 The percentage corresponding to the maxi-mum positive voltage of terminal AI1 02-36 P.546 The percentage corresponding to theminimum input current/voltage of AI202-16 P.512 The minimum input negative voltage of AI1 02-37 P.547 The percentage corresponding to themaximum input current/voltage of AI202-17 P.513 The maximum input negative voltage of AI102-18 P.510 The percentage corresponding to the mini-mum negative voltage of termianl AI102-39 P.524 DIH input minimum frequency02-40 P.525 DIH input maximum frequency02-19 P.511 The percentage corresponding to the maxi-mum negative voltage of termianl AI1 02-41 P.522 The percentage corresponding to DIH inputminimum frequency02-42 P.523 The percentage corresponding to DIH inputmaximum frequency04-20 P.132 Programmed operation mode speed 204-21 P.133 Programmed operation mode speed 302-44 P.543 FM output function selection 04-22 P.134 Programmed operation mode speed 402-45 P.64 AO1 output signal selection 04-23 P.135 Programmed operation mode speed 502-46 P.191 AO1 output gain 04-24 P.136 Programmed operation mode speed 602-47 P.190 AO1 output bias 04-25 P.137 Programmed operation mode speed 702-48 P.538 AO2 output signal selection 04-26 P.138 Programmed operation mode speed 802-49 P.536 AO2 output gain 06-17 P.261 Maintenance alarm function02-50 P.535 AO2 output bias 06-40 P.288 Alarm code query