575. Parameter DescriptionEaton Electric General Inverters DF1 Series UMXXXXXXXXE February 2020 www.eaton.com• When in password protection, parameters cannot be read. (00-03=“3”)Exception The parameters below can still be read:Group No. Name Group No. Name03-62 P.588 Monitor expanded Slot 2 digital outputterminal state06-58 P.754 E1 alarm output voltage06-59 P.755 E1 alarm the temperature rising accumula-tion rate06-01 P.22 Stall prevention operation level06-08 P.155 Over torque detection level 06-60 P.756 E1 alarm PN voltage06-11 P.160 Stall level when restart 06-61 P.757 E1 alarm the time of inverter has run06-21 P.705 Low voltage level 06-62 P.758 E1 alarm inverter operation status code06-22 P.706 Regenerative brake operation level 06-63 P.759 E1 alarm (years/months)06-23 P.707 Regenerative brake operation level 06-64 P.760 E1 alarm (days/hours)06-25 P.709 Capacitor lifetime detection level 06-65 P.761 E1 alarm (minutes/seconds)06-27 P.292 Accumulative motor operation time (minutes) 06-70 P.766 E2 alarm output frequency06-28 P.293 Accumulative motor operation time (days) 06-71 P.767 E2 alarm output current06-29 P.296 Accumulative motor power time (minutes) 06-72 P.768 E2 alarm output voltage06-30 P.297 Accumulative motor power time (days) 06-73 P.769 E2 alarm the temperature rising accumula-tion rate06-41 P.289 Alarm code display06-43 P.291 Alarm message display 06-74 P.770 E2 alarm PN voltage06-44 P.740 E1 06-75 P.771 E2 alarm the time of inverter has run06-45 P.741 E2 06-76 P.772 E2 alarm inverter operation status code06-46 P.742 E3 06-77 P.773 E2 alarm (years/months)06-47 P.743 E4 06-78 P.774 E2 alarm (days/hours)06-48 P.744 E5 06-79 P.775 E2 alarm (minutes/seconds)06-49 P.745 E6 07-17 P.802 CANopen communication status06-50 P.746 E7 07-18 P.803 CANopen control status06-51 P.747 E8 09-13 P.124 Expansion card version06-52 P.748 E9 10-52 P.265 Overexcitation current level06-53 P.749 E10 11-13 P.402 Speed limit06-54 P.750 E11 11-14 P.403 Speed limit bias06-55 P.751 E12 14-20 P.618 Current value of curling radius06-56 P.752 E1 alarm output frequency 14-32 P.630 Actual line speed06-57 P.753 E1 alarm output currentGroup No. Name Group No. Name00-00 P.90 The inverter model 03-60 P.586 Monitor noumenon and expanded Slot 3output terminal state00-01 P.188 Firmware version00-05 P.295 Password setup 03-61 P.587 Monitor expanded Slot 2&3 digital inputterminal state00-08 P.37 Speed display00-16 P.79 Operation mode selection 03-62 P.588 Monitor expanded Slot 2 digital outputterminal state00-25 P.990 Parameter mode setting00-26 P.125 Expansion card type 06-25 P.709 Capacitor lifetime detection level01-00 P.1 Maximum frequency 06-41 P.289 Alarm code display01-01 P.2 Minimum frequency 06-43 P.291 Alarm message display03-59 P.585 Monitor noumenon digital input terminalstate06-44 P.740 E106-45 P.741 E2