454. Primary OperationEaton Electric General Inverters DF1 Series UMXXXXXXXXE February 2020 www.eaton.com4.3.7 Basic operation procedures for combined mode 3(00-16(P.79)=6)4.3.8 Basic operation procedures for combined mode 4(00-16(P.79)=7)4.3.9 Basic operation procedures for combined mode 5(00-16(P.79)=8)4.3.10 Basic operation procedures for the second operation mode(00-16(P.79)=99999)• In the second operation mode, the target frequency is determined by 00-17(P.97), and the operation instruction isdetermined by 00-18 (P.109), please refer to Section 5.1.9. Operation mode selection for related description andSection 4.3.1~4.3.5 for related operation method.Step Description1 • In Combined Mode 5, indicating lamp PU will light up.ote:N For selecting and switching the operation mode, please refer to Section 4.2.2• The target frequency of the inverter is set by DXF-KEY-LED parameter unit:• When RL, RM, RH and REX of multi-speed stage levels are “on”, the target frequency is determined by combination of multi-speedstage levels (please refer to 04-00~04-02/P.4~P.6, 03-00~03-05/P.80~P.84 / P.86, 03-06 (P.126) / 03-09 (P.550)).• When external JOG is “on”, the target frequency is determined by 01-13 (P.15). Acceleration / deceleration time is set by the value of01-14 (P.16).3• The inverter starting is activated by the external forward and reverse terminals.ote:N 1. For detailed operation flow for the monitor mode, please refer to Section 4.2.3.2. While the motor is running, the user can enter into the frequency setting mode to change the target frequency for regulating the motorspeed.4 • When the digital input terminals stop the output signals, the motor will decelerate until it comes to a full stop.• Indicating lamp FWD or REV will not turn off until the inverter stops the output.Step Description1 • In Combined Mode 3, indicating lamp PU will light up.ote:N For selecting and switching the operation mode, please refer to Section 4.2.2• The target frequency is determined by communication:• When RL, RM, RH and REX of multi-speed stage levels are “on”, the target frequency is determined by combination of multi-speedstage levels (Please refer to 04-00~04-02 / P.4~P.6, 03-00~03-05 /P .80~P.84 / P.86, 03-06(P.126), 03-09(P.550)).• When external JOG is “on”, the target frequency is determined by 01-13(P.15). Acceleration / deceleration time is set by the value of01-14 (P.16).3• The inverter starting is activated by the external Run Forward or Run Reverse terminals. At this point, indicating lamp FWD or REVwill light up, indicating that the motor is running.• The functions of 00-02 (P.996 / P.998 / P.999) can be accomplished by communication.ote:N For detailed operation flow for the monitor mode, please refer to Section 4.2.3.4 • When the digital input terminals stop the output signals, the motor will decelerate until it comes to a full stop.• Indicating lamp FWD or REV will not turn off until the inverter stops the output.Step Description1 • In Combined Mode 4, indicating lamp PU will light up.ote:N For selecting and switching the operation mode, please refer to Section 4.2.2 • The target frequency of the inverter is determined by the external terminals’ “external voltage signal”, “external current signal”, or“combination of multi-speed stage levels”.3• The inverter starting is activated by communication (including “Reset”). At this point, indicating lamp FWD or REV will light up,indicating that the motor is running.ote:N 1. For detailed operation flow for the monitor mode, please refer to Section 4.2.3..2. While the motor is running, the user can enter into the frequency setting mode to change the target frequency for regulating the motorspeed.4 • When communication sends the stop instruction, the motor will decelerate until it comes to a full stop.• Indicating lamp FWD or REV will not turn off until the inverter stops the output.