EATON DGM**-5 30 Design E-VLVI-SS001-E1 October 2015N-17NSystemStak™ Internal Pilot Operated Sequence ValvesFunctional SymbolsModel CodeDGMR1General DescriptionThese two-stage pressure operated valves are normallyclosed to flow through the main spool flow path. Whensystem pressure reaches or exceeds the valve setting, themain spool flow path opens. Pilot flow may be externally orinternally drained to tank.Any pressure in the line to which these valves are drained isadditive to the valve pressure setting.The valve pressure setting is adjustable by means of eitheran adjustable screw containing an internal hex, a hand-adjustknob, or a micrometer knob with keylock. Different springratings cover an overall pressure range from 5 to 315 bar(75-4500 psi).PPT BT BT AT ABBAADGMR1-5-PP -**-*-30PPT BT BT AT ABBAADGMR1-5-PP -**-E-*-30G G DRValve functionManifold or subplate mountedsequence valve.Interface5 – ISO 4401-AC-05-4-A, CETOP RP35HSize 5 ANSI/NFPA D05Port operated uponP – Pressure portPilot controlP – Pressure portPressure rangeA – 5 to 50 bar (75 to 725 psi)B – 5 to 100 bar (75 to 1450 psi)F – 5 to 200 bar (75 to 2900 psi)G – 5 to 315 bar (75 to 4500 psi)Adjustment deviceH – Knob adjusterK – Micrometer knob with keylockW – Screw with locknutExternal drainE – External drainOmit for internal drain models.Gage port & thread typeGage port (all models), external drain (E)(optional).B – G 1/8” (1/8” BSPF)S – SAE-4 O-ring boss port(0.4375-20 UNF-2B thread)Design mumber - 30 seriesSubject to change. Installationdimensions unaltered for designnumbers 30 to 39 inclusive.DGMR1 - 5 - P P - * * - (E) - * - 301 7 93 4 5 6 82123465789