EATON DGM**-5 30 Design E-VLVI-SS001-E1 October 2015N-29NSystemStak™ Pilot Operated Check ValvesDGMPCGeneral DescriptionThese valves are single or dual check units. Dual check unitshave identical check elements located in the “A” and “B”cylinder port lines. The check valve poppets are moved intothe open position by a central pilot control spool which movestoward one check or the other, depending on which port ispressurized.The check valve located in the return circuit is opened by theoperating pressure in the primary circuit. When the pressurein the pilot line is vented, the check valve will remain closed.The pilot spool area to valve seat ratio is 3:1 on standardmodels, and 20:1 on models with the decompression feature.Check valve cracking (opening) pressures of 1 bar (15 psi),2,5 bar (36 psi) and 5 bar (73 psi) are available. Please notethat back pressure on the downstream or free-flow side ofthe pilot check valve may prevent the valve from openingin certain situations. (Back pressure opposes pilot pressuretrying to open the valve.) In such cases, pilot pressurerequired to open the decompression poppet and valve can becalculated as follows:To open valve or poppet in line A:To open valve or poppet in line B:Where:P A = Pressure at AP C = Cracking pressureP A1 = Pressure at A1PB = Pressure at BP B1 = Pressure at B1In the above cases, substitute cracking pressure and arearatio from the following:Cracking pressure: 1, 2.5 or 5 bar according to model codeposition 6 (and position 10 for second function).Area ratio factors:Standard valve: 3Decompression poppet: 20PA + PC - PA1Area ratio factorPressure at B 1 = + P A1PB + PC - PB1Area ratio factorPressure at A 1 = + P B1Model CodeValve functionManifold or subplate mounted checkvalve.Interface5 – ISO 4401-AC-05-4-A, CETOPRP35H, Size 5 ANSI/NFPA D05Decompression featureD – With decompression featureBlank – Standard (no decompression)Check portA – Check in cylinder port “A”B – Check in cylinder port “B”(single check models only)Pilot portA – Pilot port controlling the “B” portcheck (single check models only)B – Pilot port controlling the “A” portcheckCracking pressureK – 1,0 bar (15 psi)M – 2,5 bar (35 psi)N – 5,0 bar (75 psi)Decompression featureD – Decompression featureBlank – Standard (no decompression)Omit for single check models.Check port: second functionB – Check in cylinder port “B”Omit for single check models.Pilot port: second functionA – Pilot port controlling the “B” portcheck (dual check models only)Omit for single check models.Cracking pressure:second functionK – 1,0 bar (15 psi)M – 2,5 bar (35 psi)N – 5,0 bar (75 psi)Omit for single check models.Design number - 30 seriesSubject to change. Installationdimensions unaltered for designnumbers 30 to 39 inclusive.DGMPC - 5 - (D) - * * * - D B A * - 301 114 5 6 9 10872 31234567891011