EATON DGM**-5 30 Design E-VLVI-SS001-E1 October 2015N-19NInstallation DimensionsDGMR1-5-PP-**-30Sequence Valvemm (inches)See page 37 for optional adjustment devices.See page 38 for interface dimensions.*External drain and gage port threads“S” models - SAE-4 O-ring boss port(0.4375-20 UNF-2B thread).“B” models - G 1/8 (1/8 BSPF)Note: Back pressure in drainis added to this setting forinternal drain models only.* Gage port. Externalconnection port thread60(2.36)10(0.39)30,5(1.20)48(1.89) “W” models (max. ext.)Wrench size11,5(0.45)ISO 4401-AC-05-4-A (NFPA D05)Mounting surface13,5(0.53)4 mounting holes6,9 (0.27) through9,50 (0.37) counterbore46,5 (1.83) deepfor bolt extenders(order separately)BKE-6M-60M (M6 metric) orBKE-4-60M (.2500-20 UNC).Torque: 11,3-14,7 Nm(100-130 lb. in.)130(5.12)37(1.46)11,7(0.46)28,4(1.12)69,5(2.74)71,6(2.82)max.20,4(0.80)Adjust clockwise to increasepressure setting.*External drain port. Plugged for internal drain* Gage port. Externalconnection port threadT BBPAT A128(5.04)3rd angleprojection13 (1/2”)Hex key 4 (5/32”)