ASTAT XL User Manual Fout! Stijl niet gedefinieerd.DET-812 114.2.3 Minimum and Maximum Current SettingsThe ASTAT XL's minimum and maximum full load current settings depend on the model:In-line connection Inside delta connectionModel Minimum Maximum Minimum MaximumQLxxB0023D 5 A 23 A 5 A 34 AQLxxB0043D 9 A 43 A 9 A 64 AQLxxB0050D 10 A 50 A 10 A 75 AQLxxB0053D 11 A 53 A 11 A 79 AQLxxB0076D 15 A 76 A 15 A 114 AQLxxB0097D 19 A 97 A 19 A 145 AQLxxB0100D 20 A 100 A 20 A 150 AQLxxB0105D 21 A 105 A 21 A 157 AQLxxB0145D 29 A 145 A 29 A 217 AQLxxB0170D 34 A 170 A 34 A 255 AQLxxB0200D 40 A 200 A 40 A 300 AQLxxB0220D 44 A 220 A 44 A 330 AQLxxB0255D 51 A 255 A 51 A 382 AQLxxX0255D 51 A 255 A 51 A 382 AQLxxB0350D 70 A 350 A 70 A 525 AQLxxX0360D 72 A 360 A 72 A 540 AQLxxX0380D 76 A 380 A 76 A 570 AQLxxB0425D 85 A 425 A 85 A 638 AQLxxX0430D 86 A 430 A 86 A 645 AQLxxB0500D 100 A 500 A 100 A 750 AQLxxB0580D 116 A 580 A 116 A 870 AQLxxX0620D 124 A 620 A 124 A 930 AQLxxX0650D 130 A 650 A 130 A 975 AQLxxB0700D 140 A 700 A 140 A 1050 AQLxxX0790D 158 A 790 A 158 A 1185 AQLxxB0820D 164 A 820 A 164 A 1230 AQLxxB0920D 184 A 920 A 184 A 1380 AQLxxX0930D 186 A 930 A 186 A 1395 AQLxxB1000D 200 A 1000 A 200 A 1500 AQLxxX1200D 240 A 1200 A 240 A 1800 AQLxxX1410D 282 A 1410 A 282 A 2115 AQLxxX1600D 320 A 1600 A 320 A 2400 A