ASTAT XL User Manual Fout! Stijl niet gedefinieerd.DET-812 53CAUTIONContinued use of Emergency Run is not recommended. Emergency Run may compromise thestarter life as all protections and trips are disabled.Using the starter in 'Emergency Run' mode will void the product warranty.15D – Current CalibrationRange: 85% - 115% Default: 100%Description: Calibrates the soft starter's current monitoring circuits to match an externalcurrent metering device.Use the following formula to determine the necessary adjustment:Calibration (%) = Current shown on ASTAT XL displayCurrent measured by external deviceeg 102% = 66A65ANOTEThis adjustment affects all current-based functions and protections.15E – Shorted SCR ActionOptions: 3-Phase Control Only (default)PowerThroughDescription: Selects whether the soft starter will allow PowerThrough operation, if the softstarter is damaged on one phase. The soft starter will use two-phase control,allowing the motor to continue operating in critical applications.• PowerThrough can only operate with internally bypassed soft starters.• PowerThrough is only available with in-line installations. If the starter isinstalled inside delta, PowerThrough will not operate.• PowerThrough remains active until '3-Phase Control Only' is reselected.A shorted SCR or a short within the bypass contactor will trip the starter on‘Lx-Tx shorted’. If PowerThrough is enabled, the trip can be reset andsubsequent starts will use PowerThrough two-phase control; however notall features will be available. The trip LED will flash and the display willindicate ‘2 Phase - Damaged SCR'.CAUTIONPowerThrough uses a two-phase soft start technology and additional care is required whensizing circuit breakers and protection. Contact your local supplier for assistance.NOTEPowerThrough remains active until '3-Phase Control Only' is reselected.PowerThrough operation does not support Adaptive Control soft starting or soft stopping. InPowerThrough, the ASTAT XL will automatically select constant current soft starting and timedvoltage ramp soft stopping. If PowerThrough is enabled, parameters 2C and 2B must be setappropriately.PowerThrough can only operate with internally bypassed soft starters.NOTEPowerThrough is only available with in-line installations. If the starter is installed insidedelta, PowerThrough will not operate.The starter will trip on Lx-Tx Shorted on the first start attempt after control power is applied.PowerThrough will not operate if control power is cycled between starts.15F – Jog TorqueThe ASTAT XL can jog the motor at a reduced speed, which allows precise positioning of beltsand flywheels. Jog can be used for either forward or reverse operation.Range: 20% - 100% Default: 50% |
Related manuals for GE ASTAT XL
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine