B-16 B30 Bus Differential System GE MultilinB.4 MEMORY MAPPING APPENDIX BB26FC IEC 61850 Received uinteger 7 0 to 4294967295 --- 1 F003 026FE IEC 61850 Received uinteger 8 0 to 4294967295 --- 1 F003 02700 IEC 61850 Received uinteger 9 0 to 4294967295 --- 1 F003 02702 IEC 61850 Received uinteger 10 0 to 4294967295 --- 1 F003 02704 IEC 61850 Received uinteger 11 0 to 4294967295 --- 1 F003 02706 IEC 61850 Received uinteger 12 0 to 4294967295 --- 1 F003 02708 IEC 61850 Received uinteger 13 0 to 4294967295 --- 1 F003 0270A IEC 61850 Received uinteger 14 0 to 4294967295 --- 1 F003 0270C IEC 61850 Received uinteger 15 0 to 4294967295 --- 1 F003 0270E IEC 61850 Received uinteger 16 0 to 4294967295 --- 1 F003 0Expanded FlexStates (Read Only)2B00 FlexStates, one per register (256 items) 0 to 1 --- 1 F108 0 (Off)Expanded Contact Input/Output States (Read Only)2D00 Contact Input States, one per register (96 items) 0 to 1 --- 1 F108 0 (Off)2D80 Contact Output States, one per register (64 items) 0 to 1 --- 1 F108 0 (Off)2E00 Virtual Output States, one per register (96 items) 0 to 1 --- 1 F108 0 (Off)Expanded Remote Input/Output Status (Read Only)2F00 Remote Device States, one per register (32 items) 0 to 1 --- 1 F155 0 (Offline)2F80 Remote Input States, one per register (64 items) 0 to 1 --- 1 F108 0 (Off)Oscillography Values (Read Only)3000 Oscillography Number of Triggers 0 to 65535 --- 1 F001 03001 Oscillography Available Records 0 to 65535 --- 1 F001 03002 Oscillography Last Cleared Date 0 to 400000000 --- 1 F050 03004 Oscillography Number of Cycles Per Record 0 to 65535 --- 1 F001 0Oscillography Commands (Read/Write Command)3005 Oscillography Force Trigger 0 to 1 --- 1 F126 0 (No)3011 Oscillography Clear Data 0 to 1 --- 1 F126 0 (No)Oscillography Analog Values (Read Only)3012 Oscillography Number of Triggers 0 to 32767 --- 1 F001 0User Programmable Fault Report Commands (Read/Write Command)3060 User Fault Report Clear 0 to 1 --- 1 F126 0 (No)User Programmable Fault Report Actuals (Read Only)3070 Newest Record Number 0 to 65535 --- 1 F001 03071 Cleared Date 0 to 4294967295 --- 1 F050 03073 Report Date (10 items) 0 to 4294967295 --- 1 F050 0User Programmable Fault Report (Read/Write Setting) (2 modules)3090 Fault Report 1 Fault Trigger 0 to 4294967295 --- 1 F300 03092 Fault Report 1 Function 0 to 1 --- 1 F102 0 (Disabled)3093 Fault Report 1 Prefault Trigger 0 to 4294967295 --- 1 F300 03095 Fault Report Analog Channel 1 (32 items) 0 to 65536 --- 1 F600 030B5 Fault Report 1 Reserved (5 items) --- --- --- F001 030BA ...Repeated for Fault Report 2Modbus File Transfer (Read/Write)3100 Name of file to read --- --- --- F204 (none)Modbus File Transfer Values (Read Only)3200 Character position of current block within file 0 to 4294967295 --- 1 F003 03202 Size of currently-available data block 0 to 65535 --- 1 F001 03203 Block of data from requested file (122 items) 0 to 65535 --- 1 F001 0Table B–10: MODBUS MEMORY MAP (Sheet 8 of 60)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT