GE Multilin C70 Capacitor Bank Protection and Control System 5-1195 SETTINGS 5.5 FLEXLOGIC5INPUTS/OUTPUTS:Virtual inputsVirt Ip 1 OnVirt Ip 2 OnVirt Ip 3 OnVirt Ip 64 OnFlag is set, logic=1Flag is set, logic=1Flag is set, logic=1Flag is set, logic=1INPUTS/OUTPUTS:Virtual outputsVirt Op 1 OnVirt Op 2 OnVirt Op 3 OnVirt Op 96 OnFlag is set, logic=1Flag is set, logic=1Flag is set, logic=1Flag is set, logic=1LED INDICATORS:Fixed front panelLEDsLED IN SERVICELED TROUBLELED TEST MODELED TRIPLED ALARMLED PICKUPLED VOLTAGELED CURRENTLED FREQUENCYLED OTHERLED PHASE ALED PHASE BLED PHASE CLED NEUTRAL/GROUNDAsserted when the front panel IN SERVICE LED is on.Asserted when the front panel TROUBLE LED is on.Asserted when the front panel TEST MODE LED is on.Asserted when the front panel TRIP LED is on.Asserted when the front panel ALARM LED is on.Asserted when the front panel PICKUP LED is on.Asserted when the front panel VOLTAGE LED is on.Asserted when the front panel CURRENT LED is on.Asserted when the front panel FREQUENCY LED is on.Asserted when the front panel OTHER LED is on.Asserted when the front panel PHASE A LED is on.Asserted when the front panel PHASE B LED is on.Asserted when the front panel PHASE C LED is on.Asserted when the front panel NEUTRAL/GROUND LED is on.LED INDICATORS:LED testLED TEST IN PROGRESS An LED test has been initiated and has not finished.LED INDICATORS:User-programmableLEDsLED USER 1 Asserted when user-programmable LED 1 is on.LED USER 2 to 48 The operand above is available for user-programmable LEDs 2 through 48.PASSWORDSECURITYACCESS LOC SETG OFFACCESS LOC SETG ONACCESS LOC CMND OFFACCESS LOC CMND ONACCESS REM SETG OFFACCESS REM SETG ONACCESS REM CMND OFFACCESS REM CMND ONUNAUTHORIZED ACCESSAsserted when local setting access is disabled.Asserted when local setting access is enabled.Asserted when local command access is disabled.Asserted when local command access is enabled.Asserted when remote setting access is disabled.Asserted when remote setting access is enabled.Asserted when remote command access is disabled.Asserted when remote command access is enabled.Asserted when a password entry fails while accessing a password protectedlevel of the C70.REMOTE DEVICES REMOTE DEVICE 1 OnREMOTE DEVICE 2 OnREMOTE DEVICE 2 OnREMOTE DEVICE 16 OnFlag is set, logic=1Flag is set, logic=1Flag is set, logic=1Flag is set, logic=1REMOTE DEVICE 1 OffREMOTE DEVICE 2 OffREMOTE DEVICE 3 OffREMOTE DEVICE 16 OffFlag is set, logic=1Flag is set, logic=1Flag is set, logic=1Flag is set, logic=1RESETTING RESET OPRESET OP (COMMS)RESET OP (OPERAND)RESET OP (PUSHBUTTON)Reset command is operated (set by all three operands below).Communications source of the reset command.Operand (assigned in the INPUTS/OUTPUTS RESETTING menu) sourceof the reset command.Reset key (pushbutton) source of the reset command.Table 5–12: C70 FLEXLOGIC OPERANDS (Sheet 8 of 9)OPERAND TYPE OPERAND SYNTAX OPERAND DESCRIPTION