B-14 C70 Capacitor Bank Protection and Control System GE MultilinB.4 MEMORY MAPPING APPENDIX BB21A8 Breaker flashover 1 supervision phase C 0 to 4294967295 --- 1 F300 021AA Breaker flashover 1 block 0 to 4294967295 --- 1 F300 021AC Breaker flashover 1 events 0 to 1 --- 1 F102 0 (Disabled)21AD Breaker flashover 1 target 0 to 2 --- 1 F109 0 (Self-Reset)21AE Reserved (4 items) --- --- --- F001 021B2 ...Repeated for breaker flashover 2Passwords Unauthorized Access (Read/Write Command)2230 Reset Unauthorized Access 0 to 1 --- 1 F126 0 (No)Field Unit Raw Data Settings (Read/Write Setting)2460 Field Raw Data Port 0 to 7 --- 1 F244 6 (H1a)2461 Field Raw Data Freeze 0 to 1 --- 1 F102 0 (Disabled)Remote double-point status inputs (read/write setting registers) (5 modules)2620 Remote double-point status input 1 device 1 to 32 --- 1 F001 12621 Remote double-point status input 1 item 0 to 128 --- 1 F156 0 (None)2622 Remote double-point status input 1 name 1 to 64 --- 1 F205 "Rem Ip 1"2628 Remote double-point status input 1 events 0 to 1 --- 1 F102 0 (Disabled)2629 ... Repeated for double-point status input 22632 ... Repeated for double-point status input 3263B ... Repeated for double-point status input 42644 ... Repeated for double-point status input 5IEC 61850 GGIO5 configuration (read/write setting registers) (16 modules)26B0 IEC 61850 GGIO5 uinteger input 1 operand --- --- --- F612 026B1 IEC 61850 GGIO5 uinteger input 2 operand --- --- --- F612 026B2 IEC 61850 GGIO5 uinteger input 3 operand --- --- --- F612 026B3 IEC 61850 GGIO5 uinteger input 4 operand --- --- --- F612 026B4 IEC 61850 GGIO5 uinteger input 5 operand --- --- --- F612 026B5 IEC 61850 GGIO5 uinteger input 6 operand --- --- --- F612 026B6 IEC 61850 GGIO5 uinteger input 7 operand --- --- --- F612 026B7 IEC 61850 GGIO5 uinteger input 8 operand --- --- --- F612 026B8 IEC 61850 GGIO5 uinteger input 9 operand --- --- --- F612 026B9 IEC 61850 GGIO5 uinteger input 10 operand --- --- --- F612 026BA IEC 61850 GGIO5 uinteger input 11 operand --- --- --- F612 026BB IEC 61850 GGIO5 uinteger input 12 operand --- --- --- F612 026BC IEC 61850 GGIO5 uinteger input 13 operand --- --- --- F612 026BD IEC 61850 GGIO5 uinteger input 14 operand --- --- --- F612 026BE IEC 61850 GGIO5 uinteger input 15 operand --- --- --- F612 026BF IEC 61850 GGIO5 uinteger input 16 operand --- --- --- F612 0IEC 61850 received integers (read only actual values)26F0 IEC 61850 received uinteger 1 0 to 4294967295 --- 1 F003 026F2 IEC 61850 received uinteger 2 0 to 4294967295 --- 1 F003 026F4 IEC 61850 received uinteger 3 0 to 4294967295 --- 1 F003 026F6 IEC 61850 received uinteger 4 0 to 4294967295 --- 1 F003 026F8 IEC 61850 received uinteger 5 0 to 4294967295 --- 1 F003 026FA IEC 61850 received uinteger 6 0 to 4294967295 --- 1 F003 026FC IEC 61850 received uinteger 7 0 to 4294967295 --- 1 F003 026FE IEC 61850 received uinteger 8 0 to 4294967295 --- 1 F003 02700 IEC 61850 received uinteger 9 0 to 4294967295 --- 1 F003 02702 IEC 61850 received uinteger 10 0 to 4294967295 --- 1 F003 02704 IEC 61850 received uinteger 11 0 to 4294967295 --- 1 F003 02706 IEC 61850 received uinteger 12 0 to 4294967295 --- 1 F003 02708 IEC 61850 received uinteger 13 0 to 4294967295 --- 1 F003 0270A IEC 61850 received uinteger 14 0 to 4294967295 --- 1 F003 0270C IEC 61850 received uinteger 15 0 to 4294967295 --- 1 F003 0270E IEC 61850 received uinteger 16 0 to 4294967295 --- 1 F003 0Table B–9: MODBUS MEMORY MAP (Sheet 7 of 61)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT