GE Multilin C70 Capacitor Bank Protection and Control System B-35APPENDIX B B.4 MEMORY MAPPINGB5F73 FlexLogic to Activate Groups 2 through 6 (5 items) 0 to 4294967295 --- 1 F300 05F7D Setting Group Function 0 to 1 --- 1 F102 0 (Disabled)5F7E Setting Group Events 0 to 1 --- 1 F102 0 (Disabled)Setting Groups (Read Only)5F7F Current Setting Group 0 to 5 --- 1 F001 0Setting Group Names (Read/Write Setting)5F8C Setting Group 1 Name --- --- --- F203 (none)5F94 Setting Group 2 Name --- --- --- F203 (none)5F9C Setting Group 3 Name --- --- --- F203 (none)5FA4 Setting Group 4 Name --- --- --- F203 (none)5FAC Setting Group 5 Name --- --- --- F203 (none)5FB4 Setting Group 6 Name --- --- --- F203 (none)Negative Sequence Time Overcurrent (Read/Write Grouped Setting) (2 modules)6300 Negative Sequence Time Overcurrent 1 Function 0 to 1 --- 1 F102 0 (Disabled)6301 Negative Sequence Time Overcurrent 1 Signal Source 0 to 5 --- 1 F167 0 (SRC 1)6302 Negative Sequence Time Overcurrent 1 Pickup 0 to 30 pu 0.001 F001 10006303 Negative Sequence Time Overcurrent 1 Curve 0 to 16 --- 1 F103 0 (IEEE Mod Inv)6304 Negative Sequence Time Overcurrent 1 Multiplier 0 to 600 --- 0.01 F001 1006305 Negative Sequence Time Overcurrent 1 Reset 0 to 1 --- 1 F104 0 (Instantaneous)6306 Negative Sequence Time Overcurrent 1 Block 0 to 4294967295 --- 1 F300 06308 Negative Sequence Time Overcurrent 1 Target 0 to 2 --- 1 F109 0 (Self-reset)6309 Negative Sequence Time Overcurrent 1 Events 0 to 1 --- 1 F102 0 (Disabled)630A Reserved (7 items) 0 to 1 --- 1 F001 06311 ...Repeated for Negative Sequence Time Overcurrent 2Capacitor bank overvoltage settings (read/write, grouped, 3 modules)6330 Bank phase overvoltage 1 function 0 to 1 --- 1 F102 0 (Disabled)6331 Bank phase overvoltage 1 bus source 0 to 5 --- 1 F167 0 (SRC 1)6332 Bank phase overvoltage 1 neutral source 0 to 5 --- 1 F167 0 (SRC 1)6333 Bank phase overvoltage 1 bank ground 0 to 2 --- 1 F093 0 (Grounded)6334 Bank phase overvoltage 1 curve 0 to 3 --- 1 F094 0 (FlexCurve A)6335 Bank phase overvoltage 1 curve time multiplier 1 to 10 --- 0.01 F001 1006336 Bank phase overvoltage 1 stage 1A pickup 0.8 to 2 pu 0.001 F001 10506337 Bank phase overvoltage 1 stage 2A pickup 0.8 to 2 pu 0.001 F001 11006338 Bank phase overvoltage 1 stage 3A pickup 0.8 to 2 pu 0.001 F001 12006339 Bank phase overvoltage 1 stage 4A pickup 0.8 to 2 pu 0.001 F001 1050633A Bank phase overvoltage 1 stage 1B pickup 0.8 to 2 pu 0.001 F001 1050633B Bank phase overvoltage 1 stage 2B pickup 0.8 to 2 pu 0.001 F001 1100633C Bank phase overvoltage 1 stage 3B pickup 0.8 to 2 pu 0.001 F001 1200633D Bank phase overvoltage 1 stage 4B pickup 0.8 to 2 pu 0.001 F001 1050633E Bank phase overvoltage 1 stage 1C pickup 0.8 to 2 pu 0.001 F001 1050633F Bank phase overvoltage 1 stage 2C pickup 0.8 to 2 pu 0.001 F001 11006340 Bank phase overvoltage 1 stage 3C pickup 0.8 to 2 pu 0.001 F001 12006341 Bank phase overvoltage 1 stage 4C pickup 0.8 to 2 pu 0.001 F001 10506342 Bank phase overvoltage 1 stage 1 pickup delay 0 to 600 s 0.01 F001 60006343 Bank phase overvoltage 1 stage 2 pickup delay 0 to 600 s 0.01 F001 10006344 Bank phase overvoltage 1 stage 3 pickup delay 0 to 600 s 0.01 F001 2006345 Bank phase overvoltage 1 dropout delay 0 to 600 s 0.01 F001 256346 Bank phase overvoltage 1 block 0 to 4294967295 --- 1 F300 06348 Bank phase overvoltage 1 target 0 to 2 --- 1 F109 0 (Self-reset)6349 Bank phase overvoltage 1 events 0 to 1 --- 1 F102 0 (Disabled)634A ...Repeated for bank phase overvoltage 26364 ...Repeated for bank phase overvoltage 3Capacitor bank overvoltage actual values (read only, 3 modules)6390 Bank overvoltage 1 phase A operate voltage 0 to 65.535 pu 0.001 F001 0Table B–9: MODBUS MEMORY MAP (Sheet 28 of 61)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT