– 85 –Introduction and Operation CDT835S, PDF829S and PDT825SThe dual wattage 4-pass Calrod Heater serves both to heat the water during a wash cycle, and to heat theair during the dry cycle. Heat and air circulation are required for good dry performance. Air circulation isforced air with a power dry fan. Air enters through the ¿OOIXQQHOWKHQH[LWVWKURXJKWKHYHQW'XULQJWKHGU\F\FOHWKHKHDWHOHPHQWF\FOHVDIWHUDQLQLWLDOPLQXWHRQWLPHWRVHFRQGVRȺWKHQseconds "on" for 28 minutes during a Normal cycle with no wash boost options selected. Boost wash optionswill change the time needed due to hotter temperatures in rinse for the options and cycle selected. The tablebelow represents a normal cycle with a Heated Dry option only selected.6SHFL¿FDWLRQVThe Calrod Heating element is rated at 120 VAC.Dry SystemHeat ElementHeater SupportsHeater Clip (on Main Conduit)GasketNutTub TCO4 Pass Heater Algorithm, Dry CycleNormal with Heated DryTime (minutes) Calrod Description6 Calrod on28 &DOURG3XOVHPLQXWHRQPLQXWHRȺ14 &DOURGRȺ&RRO'RZQNormal with Temp Boost or Sani Selected6 Calrod on58 &DOURG3XOVHPLQXWHRQPLQXWHRȺHeated Dry Element AlgorithmHeater 120 VACWet DryWatts 793 625 +/- 5%Ohms 16.4 23.2 +/- 5%Amps 6.6 5.2 +/- 5%(Continued next page)