– 88 –All models covered in this guide have a Power Drysetting and on Monogram models, a Max Dry option.Components include a power dry fan assembly andduct assembly inside the door. Monogram modelsKDYHDGLȺHUHQWIDQPRWRUZKLFKHQDEOHVWZRoperation speeds. Fresh Air is pulled in from the leftside of the tub through an air intake (on past modelsthis was the ¿OOIXQQHO Models CDT835SxJ0xx, PDT825SxJ0xx andPDT835SxJ0xx use both the power dry fan and addheat during the dry cycle.Models CDT865SxJ0xx, PDT845SxJ0xx, PT855SxJ0xx,ZDT915SxJ0xx and ZDT915SxJ0xx use a hiddenheater and is non-operational during the Drysegment of the cycle. When Power Dry or Max DryRQ0RQRJUDPPRGHOV LVVHOHFWHGWKH¿QDOULQVHtemperatures are raised to provide needed heatduring dry (consult the Target / Max TemperatureLimits charts under Target Temperatures in theOperational and Cycle Information section of thisservice guide).Power Dry ComponentsPower Dry Forced Air OperationPower Dry (all models)The fan is a brushless motor and operated by 13.5VDC and runs at ~6,000 RPM.The Power Dry cycle is 50 minutes. When the cycle iscompleted, the Clean light comes on.If the Dry segment of the cycle is interruptedby opening the door, the control will advise theconsumer to press START and to close the door.If the consumer does not open the door after thecycle is complete, the fan will run another 90minutes. It will not restart if door is opened andclosed, and there will be no indication of thisoperation on the control display. The total run time ifdoor is not opened after the Clean light is cycled oncan be 140 minutes.Max Dry (ZDT800S and ZDT870S)Monogram models have both Power Dry and MaxDry options.The fan is a brushless motor and rated as dualspeed and running at ~6000 RPM for Power Dry and~10,000 RPM for Max Dry. ~6-7 VDC @ 6k RPM and12-14 VDC @ ~10k RPM.Max Dry operates the same as above.The Max Dry cycle is 90 minutes and the fan runs ata maximum speed of ~10,000 RPM. When the cycleis completed, the Clean light comes on. If the drysegment of the cycle is interrupted by opening thedoor, the control will advise the consumer to pressSTART and close the door. If the consumer does notopen the door after the cycle is complete, the fanwill run another 90 minutes. During this time thefan lowers speed to ~6k RPM, and it will not restartif the door is opened and closed. There will be noindication of this operation on the control display.The total run time if the door is not opened after theClean light is cycled on can be 180 minutes.(Continued next page)