Section 3 • Scheduled Maintenance Procedures January 20123 - 14 GS-30 • GS-32 • GS-46 • GS-47 Part No. 228901CHECKLIST B PROCEDURESB-5Test the Emergency StopGenie requires that this procedure be performedevery 250 hours or quarterly, whichever comesfirst.A properly functioning Emergency Stop is essentialfor safe machine operation. An improperlyoperating red Emergency Stop button will fail toshut off power and stop all machine functions,resulting in a hazardous situation.As a safety feature, selecting and operating theground controls will override the platform controls,except the platform red Emergency Stop button.1 Turn the key switch to ground control and pullout the red Emergency Stop button to the onposition at both the ground and platformcontrols.2 Push in the red Emergency Stop button at theground controls to the off position.Result: No machine functions should operate.3 Turn the key switch to platform control and pullout the red Emergency Stop button to the onposition at both the ground and platformcontrols.4 Push down the red Emergency Stop button atthe platform controls to the off position.Result: No machine functions should operate.Note: The red Emergency Stop button at theground controls will stop all machine operation,even if the key switch is switched to platformcontrol.Note: If in ground controls mode and the redEmergency Stop button at the platform controls ispushed in, the ground controls LCD will display,Platform EStop Depressed. The machine alarm willsound at 1 beep per second.