Section 3 • Scheduled Maintenance Procedures January 20123 - 32 GS-30 • GS-32 • GS-46 • GS-47 Part No. 228901Checklist D ProceduresD-1Check the Scissor ArmWear PadsGenie requires that this procedure be performedevery 1000 hours or annually, whichever comesfirst.Maintaining the condition of the scissor armwearpads is essential to safe machine operation.Continued use of worn out wear pads may result incomponent damage and unsafe operatingconditions.Note: Perform this procedure with the platform inthe stowed position.1 Measure the distance between the number oneinner arm cross tube and the chassis deck atthe ground controls side of the non-steer end ofthe machine. Refer to illustration 1.Result: The measurement is0.90 inch / 22.9 mm or more. Proceed to step 2.Result: The measurement is less than0.90 inch / 22.9 mm. Replace both wear pads.Refer to Repair Procedure 9-1 or 9-2,How toReplace the Scissor Arm Wear Pads.2 Measure the distance between the number oneinner arm cross tube and the chassis deck atthe battery pack side of the non-steer end ofthe machine. Refer to illustration 1.Result: The measurement is0.90 inch / 22.9 mm or more. Proceed to step 3.Result: The measurement is less than0.90 inch / 22.9 mm. Replace both wear pads.Refer to Repair Procedure 9-1 or 9-2,How toReplace the Scissor Arm Wear Pads.Illustration 1a wear padb inner arm cross tubec chassis deck3 Apply a thin layer of dry film lubricant to thearea of the chassis where the scissor arm wearpads make contact.Cross tube to chassis specificationMeasurement, minimum 0.90 inch22.9 mm