January 2012Section 4 • Repair Procedures4 - 8 GS-30 • GS-32 • GS-46 • GS-47 Part No. 228901GROUND CONTROLS2-2Machine SetupHow to Setup the Machine fromGround ControlsThe ground controls can be used to setup themachine parameters from the ground. Featuresthat can be adjusted from the ground controlsinclude machine Model, Options and Speed setup.This menu can only be entered from groundcontrols with the key switch in the ground controlsposition.Tip-over hazard. Do not adjustfunction speeds higher thanspecified in this procedure. Settingthe function speeds greater thanspecifications could cause themachine to tip over resulting indeath or serious injury.Tip-over hazard. This proceduremust only be performed by atrained service professional.Attempting this procedure withoutthe necessary skills could result indeath or serious injury.Note: Select a test area that is firm, level and freeof obstructions.1 Turn the key switch to the ground controlsposition and pull out the red Emergency Stopbutton to the on position at the platformcontrols.2 Press and hold the ground control scroll up andscroll down buttons.Ground Control Menu Buttonsa scroll down buttonb enter buttonc scroll up buttond escape buttone LCD display3 Pull out the red Emergency Stop button to theon position at the ground controls.Result: The ground controls LCD display willshow the following:4 Use the ground control menu buttons to selectmachine Model, Options and Speed Setupparameters. Follow the menu structureindicated on the ground control LCD display.