MaintenanceMICRO-SWITCHES on the OUTRIGGERSWhen the outriggers are lowered to the ground:- the overload warning system changes themeter scale- the transmission is deactivatedChecking the micro-switches of the outriggers(at every use)To check the micro-switches of the outriggers: Lower the outriggers to the ground and attemptto engage a gear.If the gear can be engaged, contact theTEREXLIFT Technical Assistance Service.Proceed on one outrigger at a time. With the outriggers up, light 4 on the load limiterpanel must be off; with the outriggers down to theground, the same light must be on. Should it notbe the case, contact the TEREXLIFT TechnicalService.WARNINGIf a micro-switch is faulty or a lever is deformed,immediately replace the part.AAAEmergency stop pushbuttonOn the dashboard, to the right of the steering wheel.Pressing down this button stops the engine ofthe machine.Before starting work again, find and rectify therelevant causes, then reset the button to neutralposition turning it clockwise.Checking the emergency stop pushbutton (atevery use)To check the efficiency of this pushbutton, simplypress it down during a movement. The pressure ofthe pushbutton shall cause the movement to stopand the engine to shut down.Operator’s ManualFirst Edition - Second PrintingPart No. 57.0009.0540 GTH-4013 SX - GTH-4017 SX - GTH-4013 EX - GTH-4017 EX 117Courtesy of Crane.Market