GB 14 02 02 MAMaintenanceT199-0001T199-00013. Pull out the clip A and pulldown connecting piece B.The entire valve assemblycan now be pulled out.4. Check cord and valve flapassembly C for wear,replace seal D and assem-ble again.5. Assemble the valve as-sembly again using a newvalve seat E. Lubricate O-rings F before assembly.6. Fit clip A again.NOTE! Check function ofvalve with clean water beforefilling chemicals into the tank.Nozzle tubes and fittingsPoor seals are usually caused by:• Missing O-rings or gaskets• Damaged or incorrectly seated O-rings• Dry or deformed O-rings or gaskets• Foreign bodiesIn case of leaks:DO NOT overtighten. Disas-semble, check condition andposition of O-ring or gasket.Clean, lubricate and reassemble.The O-ring must be lubricatedALL THE WAY ROUND beforefitting on to the nozzle tube. Usenon-mineral lubricant.For RADIAL connections only hand-tighten them.For AXIAL connections, a little mechanical leverage maybe used.T199-0002LeLeLeLeLevvvvvel indicael indicael indicael indicael indicator adjustmenttor adjustmenttor adjustmenttor adjustmenttor adjustmentThe level indicator reading should be checked regularly.When the tank is empty, the float should lie on the stoppin, of the rod, and the O-ring on the indicator should bepositioned at the topposition line A.If any deviation is found,pull out the plug B, loosenscrews C, and adjust thelength of the cord.CorCorCorCorCord rd rd rd rd reneeneeneeneenewwwwwal, leal, leal, leal, leal, levvvvvel indicael indicael indicael indicael indicatortortortortorIf the cord on the level indicator has to be changed, thefloat guide pole is removed:1. Remove the tank drain valve (see paragraph “Maintank drain valve”) and loosen the fitting holding thepole in position.2. Pull the pole down through the drain valve hole till it isfree in the top of the tank.3. The pole can now be taken out of the tank through thefilling hole.DANGER! Do not attempt to enter the tank - thefloat pole can be removed from outside the tank!Seal rSeal rSeal rSeal rSeal reneeneeneeneenewwwwwal, dral, dral, dral, dral, drain vain vain vain vain valvalvalvalvalveeeeeIf the main tank drain valve leaks, the seal and seat canbe changed the following way.DANGER! Do not enter the inside of the tank -the parts can be changed from underneath thetank!WARNING! Use eye / face protection mask whendismantling the tank drain valve!1. Make sure the tank is empty and clean.2. The valve must be closed and the string loose.ABCT191-0018T191-0016