Table 21. IBM Flex System p260 Compute Node and IBM Flex System p460 Compute Node LEDs (continued)Callout Unit LEDs▌3▐ DRV1 LED (HDD or SSD)▌4▐ Drive board LED (solid-state drive interposer, which is integrated in the cover)▌5▐ Management card LED▌6▐ System board LED▌7▐ Light path power LED▌8▐ DIMM LEDs▌9▐ ETE connector LEDLight path diagnostics LEDsUse the descriptions of the LEDs to diagnose the problem and to take corrective action.Table 22 describes the LEDs on the system board and the suggested actions for correcting any detectedproblems.Table 22. Light path diagnostic LED information for the IBM Flex System p260 Compute Nodev Follow the suggested actions in the order in which they are listed in the Action column until the problem issolved.v See Chapter 7, “Parts listing for IBM Flex System p260 and p460 Compute Nodes,” on page 97 to determinewhich components are CRUs and which components are FRUs.v If an action step is preceded by Trained service technician only, that step must be performed only by a trainedservice technician.Light pathdiagnostics LED islit Description ActionNone An error occurred and cannot be isolated, orthe service processor failed.An error occurred that is not represented by alight path diagnostics LED. Check the eventlog for information about the error.Battery errorP1-E1A battery error occurred. Replace the battery, as described in “Removingthe battery” on page 64 and “Installing thebattery” on page 65.DIMM x errorP1-C1 DIMM 1P1-C2 DIMM 2P1-C3 DIMM 3P1-C4 DIMM 4P1-C5 DIMM 5P1-C6 DIMM 6P1-C7 DIMM 7P1-C8 DIMM 8P1-C9 DIMM 9P1-C10 DIMM 10P1-C11 DIMM 11P1-C12 DIMM 12P1-C13 DIMM 13P1-C14 DIMM 14P1-C15 DIMM 15P1-C16 DIMM 16A memory error occurred. 1. Verify that the DIMM indicated by the litLED is a supported memory module, asdescribed on the ServerProven website.2. Replace the DIMM indicated by the litLED, as described in “Removing a DIMM”on page 55 and “Installing a DIMM” onpage 58.Note: Multiple DIMM LEDs do notnecessarily indicate multiple DIMM failures. Ifmore than one DIMM LED is lit, replace oneDIMM at a time until the error goes away.488 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide