Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- ENERGY STAR
- Communication Statements
- European Union (EC) Electromagnetic Compatibility Directives
- Electrical Safety
- Trademarks and Service Marks
- Safety Inspection
- Inspect Mechanical Parts
- Inspect Electrical Parts
- Preface
- Printing Conventions In This Manual
- Related Documents
- About The Printer
- How To Identify The Printer
- Printer Configuration Code
- Forms Handling
- Important Maintenance Notes
- Controls And Indicators
- Mechanical Controls: Figure 6
- Diagnosing Problems
- Start Of Call
- How To Troubleshoot
- Troubleshooting Display Messages
- Operator Panel Message 301 - 305
- Troubleshooting Other Symptoms
- Communication Problems
- General Symptom List
- operator panel
- power stacker
- print quality
- printer operation
- Diagnostics
- Operator Print Tests
- Selecting And Running Tests
- Customer Engineer (CE) Tests
- Boot Diagnostics Menu
- Hex Code Printout
- Printer Information Menu
- Soft vs. Hard Reset
- Controller Board Status LEDs At Power Up
- Troubleshooting A New Installation
- RibbonMinder
- ribbon action
- The Ribbon Log
- Downloading Microcode From IBM First
- Clear NVRAM
- Loading Flash Memory
- Loading Through The Serial Or Parallel Port
- Loading Through the Network Interface Card (NIC)
- Reprogramming the Security Key
- Shuttle Electrical Shorts Test
- Hammer Bank Power Cable Shorts Test
- Cable Shorts Test
- Main Wire Harness Test Diagnostic
- Power Supply Operational Check
- Locations
- Circuit Diagrams, Circuit Boards, Cables, and Switches
- interconnection diagram
- power distribution diagram
- Removals and Adjustments
- Preparing The Printer For Maintenance
- Restoring The Printer To Operation
- Removal And Replacement Procedures
- Belt, Paper Feed Timing
- Belt, Platen Open
- Circuit Board: PSA3 Controller
- Circuit Board: Power Supply
- Circuit Breaker
- Connector Shells
- Cover Assembly, Hammer Bank / Ribbon Mask
- Cover Assembly, Shuttle
- Cover Assembly, Top, Pedestal Model
- Dashpot
- Ethernet Interface Assembly
- Fan Assembly, Cabinet Exhaust
- Fan Assembly, Card Cage
- Fan Assembly, Hammer Bank
- Hammer Spring Assembly
- IBM Coax/Twinax Expansion Board
- Magnetic Pick-up (MPU) Assembly
- Memory Modules and Security Key
- Motor Assembly, Paper Feed
- Motor Assembly, Platen Open
- Motor Assembly, Ribbon Drive
- Operator Panel Assembly
- Paper Guide Assembly
- Paper Ironer
- Platen
- Platen Stop Assembly
- Resistors, Terminating
- controller board
- Ribbon Guide Assembly (L/R)
- RibbonMinder** Sensor
- Shaft, Splined
- Shaft, Support
- Shuttle Frame Assembly
- Spring, Extension, Hammer Bank
- Switch Assembly, Paper Detector
- Switch Assembly, Platen Interlock
- Tractor (L/R)
- Adjustment Procedures
- Belt, Paper Feed Timing, Adjustment (Figure 24)
- Belt, Platen Open, Adjustment (Figure 25)
- Paper Scale Alignment (Figure 26)
- Platen Gap Adjustment (Figure 27)
- Ribbon Guide Alignment (Figure 28)
- Adjusting The End Of Forms Distance
- Hammer Phasing Adjustment
- Coil Temperature Adjustment
- Dynamic Paper Tension Adjustment
- Tractor Belt Tension Adjustment
- Ethernet Initialization
- Parts Catalog
- Preventive Maintenance
- Cleaning The Printer
- Cleaning The Interior
- Cleaning The Shuttle Frame Assembly
- Cleaning The Card Cage Fan Assembly
- A Installing And Relocating The Printer
- B Communication Adapters
- Ethernet Troubleshooting Tips
- C Power Cords And Adapters
- D ASCII Codes
- E SureStak** Power Stacker
- Introduction
- How To Operate The Power Stacker
- Stacker Problems
- Removing The Power Stacker
- Installing The Power Stacker
- Replacing The Constant Force Spring
- Replacing The Timing Belts
- Replacing The Roller Drive Shaft
- Illustrated Parts Breakdown
- F Printer Specifications
- Ribbon Specifications
- warranty information
- Paper Specifications
- Labels
- Environmental Characteristics
- Electrical Characteristics
- Interfaces
- Printing Rates
- G Metric Conversion Tables
- Torque and Force
- Temperature
- H Torque Table
- I Abbreviations
|
European Union (EC) Electromagnetic Compatibility Directives16Informationen in Hinsicht EMVG Paragraph 3 Abs. (2) 2:Das Gerät erfüllt die Schutzanforderungen nach EN 55022 Klasse A und EN 50024.EN 55022 Klasse A Gerdte müssen mit folgendem Warnhinweis versehen werden: Warnung: dies ist eine Einrichtung derKlasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen öerursachen; in diesem Fall kann vom Betreiber verlangtwerden, angemessene Maßnahmen durchzuführen und dafür aufzukommen.EN 55024 Hinweis:Wird dieses Gerät in einer industriellen Umgebung betrieben (wie in EN 55024 festgelegt), dann kann es dabei eventuellgestört werden. In solch einem Fall ist der Abstand bzw. die Abschirmung zu der industriellen Störquelle zu öergrvßern.Anmerkung:Um die Einhaltung des EMVG sicherzustellen sind die Geräte, wie in den Handbüchern angegeben, zu installieren und zubetreiben.European Union (EC) Electromagnetic Compatibility DirectivesThis product conforms to the protection requirements of EC Council Directive 89/336/EEC on the approximation of the laws ofthe Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy theprotection requirements resulting from a non-recommended modification of the product, including the fitting of non-IBM optioncards.Dieses Gerät ist berechtigt in Übereinstimmung mit dem deutschen EMVG vom 9.Nov.92 das EG-Konformitätszeichen zufurhren.Properly shielded and grounded cables and connectors must be used to reduce the potential for causing interference to radioand TV communication and to other electrical or electronic equipment. IBM cannot be responsible for any interference causedby using other than recommended cables and connectors.This product has been tested and found to comply with limits for Class A Information Technology Equipment according toCISPR 22/European Standard EN 55022. The limits for Class A equipment were derived for commercial and industrialenvironments to provide reasonable protection against interference with licensed communication equipment.Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the usermay be required to take adequate measures.Dieses Gerät erfüllt die Bedingungen der EN 55022 Klasse A. Für diese Klasse von Geräten gilt folgende Bestimmung nachdem EMVG:Geräte dürfen an Orten, für die sie nicht ausreichend entstört sind, nur mit besonderer Genehmigung des Bundesminesters fürPost und Telekommunikation oder des Bundesamtes für Post und Telekommunikation betrieben werden. Die Genehmigungwird erteilt, wenn keine elektromagnetischen Störungen zu erwarten sind.
PreviousNext |